AC101
Preliminary Data Sheet
06/04/01
B r o a d c o m
Page 28
MII-Specified Registers
Document AC101-DS01-405-R¥¥¥¥¥
R
EGISTER
6: A
UTO
-N
EGOTIATION
E
XPANSION
R
EGISTER
The ANeg Complete bit of Register 1: Status Register (see ”Register 1: Status Register” on page 25) must be set for this
register to be valid.
R
EGISTER
7: A
UTO
-N
EGOTIATION
N
EXT
P
AGE
T
RANSMIT
R
EGISTER
The ANeg Complete bit of Register 1: Status Register (see ”Register 1: Status Register” on page 25) must be set for this
register to be valid.
Table 20:
Register 6: Auto-Negotiation Expansion Register
Reg.bit
Name
Description
Mode
Default
6.[15:5]
Reserved
RO
0
6.4
Parallel Detec-
tion Fault
• 1 = Fault detected by parallel detection logic, this fault is due
to more than one technology detecting concurrent link up
condition. This bit can only be cleared by reading Register 6
using the management interface.
• 0 = No fault detected by parallel detection logic.
RO/LH
0
6.3
Link Partner
Next Page Able
• 1 = Link partner supports next page function.
• 0 = Link partner does not support next page function.
RO
0
6.2
Next Page Able
Next page is supported.
RO
1
6.1
Page Received
This bit is set when a new link code word has been received
into the Auto-Negotiation Link Partner Ability Register. This bit
is cleared upon a read of this register.
RC
0
6.0
Link Partner
ANeg-Able
• 1 = Link partner is Auto-Negotiation capable.
• 0 = Link partner is not Auto-Negotiation capable.
RO
0
Table 21:
Register 7: Auto-Negotiation Next Page Transmit Register
Reg.bit
Name
Description
Mode
Default
7.15
NP
• 1 = Another Next Page desired.
• 0 = No other Next Page Transfer desired.
RW
0
7.14
Reserved
RO
0
7.13
MP
• 1 = Message page.
• 0 = Unformatted page.
RW
1
7.12
ACK2
• 1 = Will comply with message.
• 0 = Can not comply with message.
RW
0
7.11
TOG_TX
• 1 = Previous value of transmitted link code word equals to 0.
• 0 = Previous value of transmitted link code word equals to 1.
RW
0
17.[10:0]
CODE
Message/Un-formatted Code Field.
RW
001