Preliminary Data Sheet
■
AC101
06/04/01
B r o a d c o m
Document AC101-DS01-405-R¥¥¥¥¥
Register Summary
Page 23
S e c t i o n 4 : R e g i s t e r D e s c r i p t i o n s
R
EGISTER
S
UMMARY
The first eight registers of the MII register set are defined by the MII specification. In addition to these required registers are
several Altima-specific registers. There are reserved registers and/or bits that are for Altima internal use only. (Register num-
bers are in Decimal format, the values are in Hex format).
Legend:
•
RW
Read and Write Access
•
SC
Self Clearing
•
LL
Latch Low until cleared by reading
•
RO
Read Only
•
RC
Cleared on Read
•
LH
Latch High until Cleared by reading
Note
When writing to registers it is recommended that a read/modify/write operation be performed, as unin-
tended bits may get set to unwanted states. This applies to all registers, including those with reserved
bits.
Table 13:
Register Summary
Register
Description
Default
MII-Specified Registers
0
Control Register
3000
1
Status Register
7849
2
PHY Identifier 1 Register
0022
3
PHY Identifier 2 Register
561B
4
Auto-Negotiation Advertisement Register
01E1
5
Auto-Negotiation Link Partner Ability Register
0001
6
Auto-Negotiation Expansion Register
0004
7
Next Page Advertisement Register
2001
Altima-Specified Registers
8-15
Reserved
XXXX
16
Polarity and Interrupt Register
03C0
17
Interrupt Control/Status Register
0000
18
Diagnostic Register
5020
19
Power Management & Loopback Register
8060
20
Cable Measurement Register
XXXX
21
Mode Control Register
0304