UL Regulatory Safety Requirements
16
Telephony Hardware Manual
3. This apparatus MUST be professionally installed.
4. The host machine MUST be hardwired earthed in accordance with EN60950, 1992,
issue 2, +A4, 1997, cl. 6.2.1.2 with an earth wire from the host machine earthing
terminal to the building earth.
5. The host machine SELV circuit is connected to the protective earthing terminal in
accordance with EN60950 cl. 2.5.
6. The host machine ISA bus pins B1, B10, or B31 (edge connectors on CPU mother-
board/backplane) MUST be less than 0.1 Ohms to host machine earthing terminal.
7. AltiGen complies with PCI Board specifications Rev. 2.1 (5V 32-bit).
8. The power required by the host machine and the total of all adapter cards installed
within the host environment, together with any ancillary apparatus, shall not exceed
the power specification of the host machine.
9. It is essential that, when other option cards are introduced that use or generate a
hazardous voltage, the minimum creepages and clearances specified in the following
table are maintained. A hazardous voltage is one that exceeds 42.4V peak AC or 60V
DC. If you have any doubt, seek advice from a competent engineer before installing
other adapters into the host machine.
For a host or other expansion card fitted in the host, using or generating voltages
greater than 300V (rms or dc), advice from a competent safety engineer must be
obtained before installation of the relevant equipment.
Any other usage will
INVALIDATE
the approval of the apparatus, if as a result, it
then ceases to conform to the standards against which approval was granted.
10. For the following AltiServ platforms — AltiServ1A-IP, AltiServ1E-IP, and Alti-Office
1B — make sure the input voltage selection switch (115/230V) is on the back of the
chassis and is set to the proper voltage for your installation.
Requisitos Reglamentarios de Seguridad de La Asociación
de Aseguradores (UL)
Computadora Principal
1. El aparato modelo AltiGen/MAX Communication Server se encuentra aprobado para
conectarse a los Sistemas de Telecomunicaciones que se especifican en estas
Clearance (mm)
Creepage (mm)
Voltage used or
generated by host
or other cards
2.0
2.4 (3.8)
Up to 50 Vrms or Vdc
2.6
3.0 (4.8)
Up to 125 Vrms or Vdc
4.0
5.0A (8.0)
Up to 250 Vrms or Vdc
4.0
6.4 (10.0)
Up to 300 Vrms or Vdc
ISA bus
ISA bus
B1
B10
B31
Summary of Contents for MAX1000
Page 1: ...Telephony Hardware Manual 12 2009 4413 0001 6 5 Update1 ...
Page 6: ...2 Telephony Hardware Manual ...
Page 14: ...FCC Requirements 10 Telephony Hardware Manual ...
Page 30: ...UL Hardware Preparation 26 Telephony Hardware Manual ...
Page 56: ...MAX2000 System 52 Telephony Hardware Manual ...
Page 66: ...Installing and Removing an Access Board 62 Telephony Hardware Manual ...