Wiring Specification
The 50-pin Telco connector (RJ-21X) on the access board requires a standard Telco cable
(Male-to-Male) to connect to a punch down block (66 Block) or a 24-port patch panel.
Refer to the following pinout specification when wiring punch down block or patch panel
to CO trunk or phones.
System Limitation for MAX1000
•
Each MAX1000 system can support only one ALTI-M0404-T1E1.
MAX1000-R System
The MAX1000-R system is similar to the MAX1000 system described above, except that
it supports
two
ALTI-M0404-T1E1 spans.
In addition, there are differences in the system resources provided by the embedded
DSP board. In the MAX1000-R, the DSP board supports:
•
Up to 96 extensions
•
6 extension-based conference bridges—6 parties per conference, with a maximum
of 24 parties at any one time
•
Up to 12 G.723/G.729/G.711 IP channels and 48 G.711-only IP channels
•
Extension recording but not trunk recording