3.2
Electromagnetic Compatibility (EMC) Requirements
Observe the following EMC requirements when setting up the Alpha FXM and its internal equipment:
All AC mains and external supply conductors must be enclosed in a metal conduit or raceway when
specified by local, national, and/or other applicable government codes and regulations.
The customer facilities must provide suitable surge protection.
To meet FCC Class B requirements, follow the instructions in section 5.1.4 to attach a ferrite ring to the
connector end of your RJ45 network cable.
3.3
Mounting Options for the Micro350 (XL and XL3)
Figure 7 shows the mounting hardware for the various configurations of the Micro350. Choose from the following
options for mounting the Micro350:
Mounting to a wooden pole, 5.1.1.1 on page 24.
Mounting to a steel or concrete pole, 5.1.1.3 on page 26.
Mounting to a wall, 5.1.1.4 on page 27.
Optional pedestal mounting is shown in Figure 8.
Micro Standard
M
i
c
r
o
Micro XL
Micro XL3
NOTE: To install a Micro XL3 enclosure, first attach
the XL to an XL3 kit.
Figure 7
— Mounting the Micro350