Montage
ASSEMBLY OF THE INSTALLED CONTROL
In the case of devices for internal mounting, the motherboard of
the heating and heat pump is integrated in the electrical switch
cabinet of the device.
Operating manual of your heat pump, assembly of the con-
trol unit
ASSEMBLY OF THE WALL CONTROL
Air/Water outdoor units standard
Operating Manual wall-mounted controller
Air/Water outdoor units professional (LWP)
For all work to be carried out:
NOTE
Observe the locally-applicable accident prevention regula-
tions, statutory provisions, ordinances and directives.
WARNING
Only qualified technicians may mount the heating and
heat pump control.
1. Position the drill template at the point where the heating
and heat pump control is to be located.
IMPORTANT
Check the potential mounting location for concealed wir-
ing. Position the drill template in such way that no con-
cealed wiring can be drilled into or damaged during the
subsequent assembly work.
NOTE
You need to ensure ≥ 2 cm free space to the right and left
of the drill template, so that there is enough space for the
side fastening screws of the housing cover.
2. Fix drill template onto the wall with adhesive tape, drill holes
(Ø 6 mm, depth ≥ 55 mm).
3. Take drill template off the wall, insert dowels in the holes,
screw in screws (spacing from the substrate to the screw
head approximately 10mm).
Scope of delivery
NOTE
Function-critical temperature sensors (return, inlet, hot
gas) are installed in the heat pump and are not part of the
scope of supply of the heating and heat pump regulator.
The heating and heat pump regulator is supplied in two variants.
The variant supplied is dependent on the device type of the heat
pump to the controlled.
INSTALLED CONTROL SCOPE OF SUPPLY
In the case of devices for internal mounting, the motherboard of
the heating and heat pump regulator is integrated in the relevant
device as an “installed control”. The “installed control” scope of
supply is included in the scope of supply of the device for inter-
nal mounting.
●
Heating and heat pump regulator,
consisting of motherboard (with terminals) and control unit
(with status display, screen and “rotary pushbutton”)
●
External sensor for the surface mounting
●
Operating manual (in two parts)
●
Brief description of the heat pump control.
NOTE
Please fasten brief description in the vicinity of the device.
WALL CONTROL SCOPE OF SUPPLY
In the case of devices for external mounting, the motherboard of
the heating and heat pump control is not integrated in the rele-
vant device but in the wall control.
●
Heating and heat pump control for surface mounting,
consisting of motherboard (with terminals), housing and
control unit (with status display, screen and “rotary push-
button”)
●
Wall mounting materials (drill template, screws, dowels
for solid masonry)
●
External sensor for the surface mounting
●
Operating manual (in two parts)
●
Brief description of the heat pump control
NOTE
Please fasten brief description in the vicinity of the device.
1. Check the supplied product for signs of external damage dur-
ing delivery.
2. Check that nothing is missing from the scope of supply.
Immediately submit a complaint in the event of delivery de-
fects.