20
Subject to technical amendments without prior notice | 83055400iUK – 2.1 | ait-deutschland GmbH
Query InfoLog
NOTE
Menu entry is only displayed if customer service access is
activated.
Errors that occur during operation of the heat pump are stored in
a list in the InfoLog. Each error is timestamped.
The error list contains a maximum of 100 entries. The last error
that occurred is at the top of the list. If there are more than 100 en-
tries, the oldest (= last) entry in the list is overwritten.
The menu is not shown in full here.
Query Inverter
NOTE
Menu entry is only displayed if customer service access
is activated. The list displayed on the screen is for service
purposes only.
The menu is not shown in full here.
Query Smart
NOTE
Menu entry is only displayed if customer service access is
activated and if:
●
Menu entry “room stat.” is set to “Smart”
●
“Smart“ settings have been made.
page 24, “Determining system setting“, “room stat.”
page 33, “Smart“
The menu is not shown in full here.
set temperature HC
Setpoint temperature heating circuit
set temperature MC1
Setpoint temperature mixing circuit 1
Targ. service water
Set point temperature domestic hot
water preparation
target value max
Highest requirement setpoint from the
Smart system
UFH total HC
Number of floor heating circuits
assigned to the heating circuit
UFH open HC
Number of open floor heating circuits
assigned to the heating circuit
numb.actuat. HC
Number of radiator drives assigned to
the heating circuit
Cur. room temp. HC
Current room temperature of the worst
room in the heating circuit
Targ. room temp. HC
Target temperature of the worst room
in the heating circuit
UFH total MC1
Number of floor heating circuits
assigned to the mixing circuit 1
UFH open MC1
Number of open floor heating circuits
assigned to the mixing circuit 1
numb.actuat. MC1
Number of radiator drives assigned to
the mixing circuit 1
Cur. room temp. MC1
Current room temperature of the worst
room in the mixing circuit 1
Targ. room temp. MC1 Target temperature of the worst room
in the mixing circuit 1