48
Subject to technical amendments without prior notice | 83055400iUK – 2.1 | ait-deutschland GmbH
Parameter
Factory setting
Adjustment during
commissioning *)
Value range (adjustable steps) Access
TDI Message
Yes
No • Yes Fitter
heat source
No
No • brine • wat./brine • water.
AS
Freig. ZWE HZ
60 min
20 min - 360 min (
↕
5) Fitter
Freig. ZWE WW
No
0 min - 120 min (
↕
5) Fitter
aux. heat. hot water
No
No • Yes
User
aux.serv.water max.
–
1 h – 10 h (
↕
0.5) Fitter
high pressure limit
device-dependent
device-dependent
Factory
low pressure limit
device-dependent
device-dependent
Factory
power 2hg
9 kW
0.5 kW – 9 kW (
↕0.
5)
User
smart grid
No
No • Yes Fitter
setting MC 1
fast
fast • medium • slow
User
Comp-Heater
Yes
No • Yes Fitter
Cooling
wo. CP
with CP • wo. ZUP Fitter
Efficiency pump
Heat distrib. sys
radiator
radiator • floor heat Fitter
control heating
Auto
Auto • Manual Fitter
output heat. nom.
100 %
1 % – 100 % (
↕
1) Fitter
output heat. Min.
100 %
1 % – 100 % (
↕
1) Fitter
Output heat. max.
100 %
50 % – 100 % (
↕
1) Fitter
Control dhw
Auto
Auto • Manual Fitter
output dhw.
100 %
1 % – 100 % (
↕
1) Fitter
output dhw max
100 %
50 % – 100 % (
↕
1) Fitter
output cooling
100 %
1 % – 100 % (
↕
1) Fitter
control VBO
Auto
Auto • Manual Fitter
output VBO
100 %
1 % – 100 % (
↕
1) Fitter
output VBO (cooling)
100 %
1 % – 100 % (
↕
1) Fitter
dT cooling
5 K
1 K – 5 K (
↕0.
1) Fitter
Set bypass valve
No
No • Yes
User
Additional heat generator
Second heat gen. 1
Type
No
No • El.Rod • Boiler • Thermal Fitter
Function
HW a SW
No • HW a SW • Heating Fitter
Position
Integrated
– – – • Integrated • Tank Fitter
Outlet
installation-dependent
– – – • (output contact) Fitter
Second heat gen. 2
Type
No
No • El.Rod Fitter
Function
No
No • Heating • SW Fitter
Position
– – –
– – – • Tank Fitter
Outlet
– – –
– – – • (output contact) Fitter
Inverter
frequ. limit start
0 Hz
0 Hz – 120 Hz (
↕
1) Fitter
frequency limit stop
0 Hz
0 Hz – 120 Hz (
↕
1) Fitter
Freq. SW
Auto
Auto • … Hz 20 Hz – 120 Hz (
↕
1)
AS
DHW
normal
normal • luxury
User
*) Please enter the adjusted values. Mark not applicable with — .