Query heat quantity
Many heat pump types are equipped with heat quantity record-
ing by pressure sensors in the cooling circuit of the heat pump. In
these heat pumps the heat quantity can be read out directly.
Heating
Recorded heat quantity for heating
DHW
Recorded heat quantity for domestic
hot water
total
Sum of the heat quantity supplied by
the heat pump
since:
Reset with date indication
By clicking on the menu line with
the date, the heat quantity meter in
this and the following menu lines are
reset to zero and the current date is
automatically entered. In this way the
heat quantity can be recorded for a
period defined by you (start date =
displayed date)
since Reset:
Reset without date indication
By clicking on this menu line, the heat
quantity meter in this menu line is reset
to zero.
NOTE
Depending on the system configuration, further entries
may appear for heat quantities recorded (e.g. for additional
heat generator, swimming pool heating, …).
Query building services management system (BMS)
The menu is not shown in full here.
NOTE
Data is only displayed if the heat pump is integrated into a
building management system. This requires a special con-
figuration of the heating and heat pump controller with
additional software that is subject to a charge.
Operating manual “Connection to a building services man-
agement system via BACnet/IP | ModBus/TCP”
NOTE
Maximum the last five disconnections are displayed.
If an entry is clicked, the corresponding information for this entry
is displayed.
Query the facility status
The menu is not shown in full here.
Type of heat pump
Type of heat pump
Software version
of the heating and heat pump
regulator
ASB SW Vers.
Software version ASB
HZ/IO
HZ/IO version
ASB HW Revision
Hardware revision ASB
Bivalent level
Bivalent level:
1 = a compressor may operate
2 = two compressors may operate
3 = additional heat generator may
operate as well
Operation mode
Current operation mode:
Heating, DHW, …
Defrost, El.Sup.bl., …
Current capacity
Heating output currently provided by
the output-controlled compressor.
This heating output can be used to
set the overflow valve in a storage
tank integrated in series according
to the setting diagram in the unit
instructions.
Capacity demand
Required output for output-controlled
compressor controlled by the heating
and heat pump controller.
Software version SEC
Software version of the inverter
controller of the output-controlled
heat pump
output max. SEC
Maximum performance SEC
Software version RBE
Software version of the room control
unit (RBE)
Defrost demand
Defrosting requirement in %
Last defrost
Time of last defrost