background image

Installation

Tumble Dryers

120 Pound (55 Kilogram) Capacity
170 Pound (77 Kilogram) Capacity
200 Pound (90 Kilogram) Capacity

Models with 0 or 3 in 13th Position of Model Number

Refer to Page 8 for Model Identification

TMB1282C_SVG

Original Instructions
Keep These Instructions for Future Reference.
CAUTION: Read the instructions before using the machine.

(If this machine changes ownership, this manual must accompany machine.)

www.alliancelaundry.com

Part No. 70532501ENR7

December 2018

Summary of Contents for BA120E

Page 1: ...3 in 13th Position of Model Number Refer to Page 8 for Model Identification TMB1282C_SVG Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www alliancelaundry com Part No 70532501ENR7 December 2018 ...

Page 2: ......

Page 3: ...nd accessories and wait five 5 minutes before servic ing W925 WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occu pants Immediately call your gas suppl...

Page 4: ...To reduce the risk of serious injury Avoid contact with hot surfaces W927 WARNING Electrical shock hazard can cause death or serious injury To reduce the risk of electric shock discon nect all electric power to appliance and accessories before servicing W929 WARNING Moving parts hazard can cause serious injury Dis connect electric power to unit before servicing Un expected start of machinery will ...

Page 5: ...t is required the dryer should not be used and a service call booked Risk of fire flammable material W926 The following information applies to the state of Massachusetts USA This appliance can only be installed by a Massachusetts li censed plumber or gas fitter This appliance must be installed with a 36 inch 91 cm long flexible gas connector A T Handle type gas shut off valve must be installed in ...

Page 6: ...move Shipping Materials 24 Position and Level the Tumble Dryer 25 Mounting 25 Fire Suppression System Optional Equipment 25 Check Local Codes and Permits 25 Water Requirements 25 Water Connections 26 Electrical Requirements 27 Auxiliary Alarm 27 Before Placing Tumble Dryer into Service 28 Required for IEC Models Only 29 Exhaust Requirements 30 Exhaust Requirements 30 Layout 30 Make Up Air 30 Venti...

Page 7: ...ram 51 Grounding Instructions 51 For On Premises Laundry OPL Models Only 52 Service Ground Location 52 To Connect Electrical Service To The Tumble Dryer 52 Electrical Specifications 53 Steam Requirements 56 Steam Requirements 56 Piping Recommendations 60 Installing Steam Trap and Making Condensate Return Connections 60 Adjustments 61 Adjustments 61 Gas Burner Air Shutter 61 Airflow Switch 62 Loadi...

Page 8: ...China Restriction of hazardous substances RoHS 68 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 8 Part No 70532501ENR7 ...

Page 9: ...0S HJ120L NG120E PA120E PT120S SR120S UJ120S BH120S GJ120E HJ120N NG120L PA120L PU120E ST120C UK120E BJ120E GJ120L HJ120S NG120N PA120N PU120L ST120E UK120L BJ120L GJ120N HK120E NG120S PA120S PU120N ST120L UK120N BJ120N GJ120S HK120L NH120E PG120E PU120S ST120N UR120E BJ120S GK120E HK120N NH120L PG120L SA120E ST120S UR120S BK120E GK120L HR120E NH120N PG120N SA120L SU120E UT120C BK120L GK120N HR120...

Page 10: ...C UJ170S BH170S GJ170L HJ170S NG170S PA170S PU170N ST170L UK170L BJ170L GJ170N HK170L NH170L PG170L PU170S ST170N UK170N BJ170N GJ170S HK170N NH170N PG170N SA170L ST170S UR170S BJ170S GK170L HR170S NH170S PG170S SA170N SU170L UT170C BK170L GK170N HT170C NJ170L PH170L SA170S SU170N UT170L BK170N GU170L HT170L NJ170N PH170N SG170L SU170S UT170N BR170S GU170N HT170N NJ170S PH170S SG170N UA170L UT170S...

Page 11: ...0N ST200L UK200L BJ200L GJ200N HK200L NH200L PG200L PU200S ST200N UK200N BJ200N GJ200S HK200N NH200N PG200N SA200L ST200S UR200S BJ200S GK200L HR200S NH200S PG200S SA200N SU200L UT200C BK200L GK200N HT200C NJ200L PH200L SA200S SU200N UT200L BK200N GU200L HT200L NJ200N PH200N SG200L SU200S UT200N BR200S GU200N HT200N NJ200S PH200S SG200N UA200L UT200S BU200L GU200S HT200S NK200L PJ200L SG200S UA200...

Page 12: ...G To reduce the risk of serious injury or death DO NOT repair or replace any part of the unit or attempt any servicing unless specifically recommended in the user maintenance instructions or in published user repair instructions that you understand and have the skills to carry out W329 If replacement parts are required contact the source from where you purchased your unit TMB2427N_SVG 120 170 200 ...

Page 13: ...en filter When you perceive a gas odor immediately shut off the gas supply and ventilate the room Do not power on electrical ap pliances and do not pull electrical switches Do not use matches or lighters Do not use a phone in the building Warn the installer and if so desired the gas company as soon as possible To avoid fire and explosion keep surrounding areas free of flammable and combustible pro...

Page 14: ...cids are corrosive to the tumble dryer as well as the laundry load being dried Be sure make up air is free of solvent vapors At the end of each working day close off all main supplies of gas steam and electricity IMPORTANT For fire suppression equipped tumble dryers electricity and water should NOT be turned off Do not repair or replace any part of the tumble dryer or at tempt any servicing unless...

Page 15: ... x 2290 52 1 x 73 8 x 99 0 1320 x 1870 x 2510 52 1 x 81 3 x 99 0 1320 x 2070 x 2510 Standard Packaging Shipping Volume ft3 m3 179 5 1 220 6 2 243 6 9 Slat Crate Packagine Shipping Dimen sions Inches Millimeters 53 0 x 74 5 x 90 9 1350 x 1890 x 2310 60 1 x 76 8 x 100 3 1530 x 1950 x 2550 60 1 x 84 3 x 100 3 1530 x 2140 x 2550 Slat Crate Packaging Shipping Volume ft3 m3 208 5 9 268 7 6 294 8 3 Cylin...

Page 16: ...nches Milli meter 27 0 686 27 0 686 27 0 686 Door Hinge Side Right Right Right Door Maximum Open Angle Degrees 180 180 180 Gas Models Gas Connection 1 NPT 1 NPT 1 NPT Gas Burner Rating Btu hr kW Mj hr 270 000 79 290 395 000 116 417 425 000 125 448 Steam Models Steam Connection 3 4 NPT inlet 3 4 NPT outlet 3 4 NPT inlet 1 NPT outlet 3 4 NPT inlet 1 NPT outlet Steam Coil Rating at 100 psig Btu hr kg...

Page 17: ...I J K 120 46 1 1170 85 7 2175 70 0 1780 28 6 725 30 1 765 58 0 1475 170 52 9 1345 94 0 2390 75 0 1905 32 7 830 34 3 870 60 8 1545 200 52 9 1345 94 0 2390 75 0 1905 32 7 830 34 3 870 60 8 1545 Fire suppression system optional may not be on machine Refer to Position and Level the Tumble Dryer to temporarily re duce the heights of these models Rear Exhaust Dimensions in mm Models Diameter Y Z Table c...

Page 18: ...nsions in mm 120 10 0 250 7 6 195 7 6 195 170 12 0 305 8 8 225 11 0 280 200 12 0 305 8 8 225 11 0 280 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 18 Part No 70532501ENR7 ...

Page 19: ...29 mm Diameter Models Electrical Connection in mm Gas Connection in mm A B C D Diameter 120 3 9 100 60 9 1545 12 9 330 70 2 1785 1 NPT 170 8 0 205 63 7 1620 14 6 370 77 4 1965 1 NPT 200 8 0 205 63 7 1620 14 6 370 77 4 1965 1 NPT Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 19 Part No 70532501ENR7 ...

Page 20: ... Models Steam Inlet in mm Diameter A1 A2 F 120 3 4 NPT 35 9 910 14 3 365 82 5 2095 170 3 4 NPT 37 6 955 15 5 395 87 6 2225 200 3 4 NPT 37 6 955 15 5 395 87 6 2225 Models Steam Outlet in mm Diameter B1 B2 D 120 3 4 NPT 34 6 880 13 1 335 68 5 1740 170 1 NPT 44 0 1120 9 0 230 72 0 1830 200 1 NPT 44 0 1120 9 0 230 72 0 1830 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT CO...

Page 21: ...ctrical Connection in mm C E 120 3 9 100 60 9 1545 170 8 0 205 63 7 1620 200 8 0 205 63 7 1620 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 21 Part No 70532501ENR7 ...

Page 22: ...els TMB2578N_SVG A B 1 1 Electrical Connection 2 5 in 64 mm Diameter Connection Dimensions in mm Models A B 120 36 4 925 85 6 2175 Specifications and Dimensions Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 22 Part No 70532501ENR7 ...

Page 23: ...ce line to be connected upstream of solenoid steam valve Two steam shut off valves for each conden sate return line Flexible steam hoses with a 125 psig pounds per square inch gauge 862 kPa working pressure for connecting steam coils Refer to Figure 16 and Figure 17 for sizing and connection configurations Two steam traps for steam coil outlets to condensate return line Optional Two vacuum breaker...

Page 24: ...nce permitted for remainder 120 Gas Electric 4 0 in 100 mm 120 Steam 12 0 in 300 mm 170 200 Gas 4 0 in 100 mm 170 200 Steam 12 0 in 300 mm 5 Guard 6 Provision for make up air 7 24 in 610 mm minimum 36 in 910 mm recommended for maintenance purposes 8 0 0 in 0 mm minimum 0 25 in 6 mm recommended for removal or installation purposes Figure 2 Remove Shipping Materials IMPORTANT Remove the yellow shipp...

Page 25: ...ain on at all times for the fire suppression system to work Check Local Codes and Permits Call your local water company or the proper municipal authority for information regarding local codes IMPORTANT It is your responsibility to have ALL plumbing connections made by a qualified professio nal to assure that the plumbing is adequate and con forms to local state and federal regulations or codes IMP...

Page 26: ...low preventer vacuum breaker before connecting to the public water main in all countries where local regulations require specific water approval certificates Two hoses and a Y connector are provided with the tumble dryer to allow for connection of water supply to tumble dryer DO NOT reuse old hose sets The water connections are made to the water solenoid valve located on the rear of the tumble dry...

Page 27: ...be provided to tumble dryer at all times The fire suppression system will be inoper ative if the main electrical power supply is discon nected W690R1 No independent external power source or supply connection is necessary Power to operate the fire suppression system is from the tumble dryer main power supply Auxiliary Alarm The fire suppression system provides an auxiliary output contact when the s...

Page 28: ...and in dicate that the ignition control needs to be reset To reset the ignition control press start key on the control The control will then prompt for the start key to be pressed again to restart the cycle On all models ignition lockout may occur due to air in the gas line or the gas shut off valve being in the OFF position If the air is bled out of the gas line the gas shut off valve is in the O...

Page 29: ...ith customer Review tumble dryer warranty information with customer Apply cautionary stickers in language appropriate to country of sale Market language label kits have been provided in the literature packet located in the cylinder Position appropriate market language labels on the tumble dryer in the following regions prior to placing tumble dryer into service if applica ble On front panel at the...

Page 30: ...0 200 Series 525 3400 Make up air openings with louvers will restrict airflow The opening must be increased to compensate for area taken up and restrictions created by louvers Contact the louver manufacturer for the exact specifications Make up air openings in rooms containing tumble dryer s and or gas fired hot water heater or other gravity vented appliances must be increased sufficiently to prev...

Page 31: ... must be constructed of sheet metal or other noncombustible material Such ducts must be equivalent in strength and corrosion resist ance to ducts made of galvanized sheet steel not less than 0 02 inches 0 50 mm thick Where the exhaust duct pierces a combustible wall or ceiling the opening must be sized per local codes The space around the duct may be sealed with noncombustible material Refer to Fi...

Page 32: ...RTANT At no point may the cross sectional area of installed venting be less than the cross sectional area of the exhaust outlet of the tumble dryer The exhaust duct must be designed so the static back pressure measured 12 inches 305 mm from the exhaust outlet does not exceed the maximum allowable pressure specified in the Specifi cations and Dimensions Table or on the installation sticker on the r...

Page 33: ...ular or square duct must be increased 20 for each additional 20 feet 6 1 m Refer to Table 2 to determine equivalent ducting sizing The collector duct may be rectangular or square in cross section as long as the area is not reduced Provisions MUST be made for lint removal and cleaning of the collector duct The vent collector system must be designed so the static back pressure measured 12 inches 305...

Page 34: ...4 in 610 mm 27 in 686 mm F 26 in 660 mm 30 in 762 mm G 28 in 711 mm 32 in 813 mm H 30 in 762 mm 34 in 864 mm I 32 in 813 mm 36 in 914 mm J 33 in 838 mm 38 in 965 mm K 35 in 889 mm 40 in 1 016 mm L 36 in 914 mm 42 in 1 067 mm Table 2 NOTE Table 2 represents tumble dryers with the same vent size If multiple vent sizes are used consult a lo cal HVAC specialist NOTE Duct clean out recommended every 6 ...

Page 35: ...A A I 1 Outlet duct diameter combined largest duct diameter of both sides 2 45 typical Figure 10 Refer to Table 2 for measurements for each manifold Exhaust Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 35 Part No 70532501ENR7 ...

Page 36: ... local codes with the latest edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 in the U S A with CAN CSA B149 1 Natural Gas and Propane In stallation Code in Canada In Australia and New Zealand installation must comply with the Gas Installations Standard AS NZS 5601 Part 1 General Installations In the EU installation must comply with the installa tion regulations of the country of destinat...

Page 37: ...ches 26 1 mbar 2 61 kPa with all gas appliances running PROPANE LIQUID PETROLEUM GAS L P G supply pres sures with all gas appliances running tumble dryers water heat ers space heaters furnace etc CSA Models AGA Models CE Models Maximum 13 in w c 3 23 kPa Refer to Table 3 Recommend ed 11 in w c 2 74 kPa Minimum 10 in w c 2 49 kPa Gas Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY o...

Page 38: ...30 37 Butane 30 28 30 25 35 G31 3 28 30 37 Propane 37 25 45 II2E3B P PL G20 2E 20 17 25 8 0 G30 3B P 30 28 30 25 35 II2E3B P LU G20 2E 20 17 25 8 0 G30 31 3B P 50 42 5 57 5 27 5 II2E3B P II2E LL 3B P DE G20 2E LL 2E 20 17 25 8 0 G25 2E LL 20 17 25 12 0 G30 31 3B P 50 42 5 57 5 27 5 II2E r 3 FR G20 2E r 20 17 25 8 0 G25 2E r 20 17 25 12 0 G30 3 30 37 Bu tane 30 28 30 25 35 G31 3 30 37 Propane 37 25...

Page 39: ...gure 1 If the manifold pres sure required adjustment refer to How to Adjust Gas Valve Gov ernor Regulator CSA Models AGA Models CE Models Natural Gas 3 5 in w c 0 87 kPa Refer to Table 3 Propane L P G 10 5 in w c 2 61 kPa The connection of gas supply to the appliance shall be made with a flexible hose suitable for the appliance category in accordance with national installation regulations of the c...

Page 40: ...valve 1 Manometer 2 Pressure Tap 3 Burner Tube Attaching Screws 4 Gas Valve Flange 5 Gas Valve 6 Specified Pressure Figure 13 2 Remove gas valve a Remove the burner orifice s from the spud holder b When converting from Natural Gas to L P Gas the left most burner and orifice viewed from front must be re moved c In place of the removed orifice a blank orifice Part No M400995 and a Burner Opening Cov...

Page 41: ...nifold pressure as applicable per Table 3 Units installed in France FR require a gas connection adapter having ISO228 BSPP G parallel threads and a sealing washer The adapter must have a sufficient flat area to seat the sealing washer Adjusting Manifold Pressure for Natural Gas G20 or G25 1 If country gas category designation required is not listed on the serial plate affix the appropriate country...

Page 42: ...s meter 11 Pressure regulator if required 12 120 series tumble dryers 270 000 Btu hr 285 Mj hr 79 kW each 170 series tumble dryers 395 000 Btu hr 417 Mj hr 116 kW each 200 series tumble dryers 425 000 Btu hr 448 Mj hr 125 kW each Figure 15 SAMPLE CALCULATIONS Equivalent length Total length of main gas supply pipe to the far end of the tumble dryers 25 ft 19 ft 7 6 m 5 8 m gas supply pipe 44 ft 13 ...

Page 43: ...0 000 3 4 1 1 1 1 1 160 000 3 4 1 1 1 1 1 4 1 1 4 180 000 3 4 1 1 1 1 4 1 1 4 1 1 4 200 000 1 1 1 1 1 4 1 1 4 1 1 4 300 000 1 1 1 4 1 1 4 1 1 4 1 1 2 1 1 2 400 000 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 1 1 2 500 000 1 1 4 1 1 2 1 1 2 1 1 2 1 1 2 2 600 000 1 1 4 1 1 2 1 1 2 2 2 2 700 000 1 1 2 1 1 2 2 2 2 2 800 000 1 1 2 1 1 2 2 2 2 2 900 000 1 1 2 2 2 2 2 2 1 2 1 000 000 1 1 2 2 2 2 2 1 2 2 1 2 1 100 000 ...

Page 44: ...shown in Gas Pipe Nominal Size NPT 1 700 000 2 2 1 2 2 1 2 2 1 2 3 3 1 800 000 2 2 1 2 2 1 2 2 1 2 3 3 1 900 000 2 2 1 2 2 1 2 3 3 3 2 000 000 2 2 1 2 2 1 2 3 3 3 2 200 000 2 2 1 2 3 3 3 3 2 400 000 2 1 2 2 1 2 3 3 3 3 1 2 2 600 000 2 1 2 2 1 2 3 3 3 1 2 3 1 2 2 800 000 2 1 2 3 3 3 3 1 2 3 1 2 3 000 000 2 1 2 3 3 3 1 2 3 1 2 3 1 2 For L P Gas correct the total Btu hr by multiplying it by 0 6 The a...

Page 45: ...2 1 2 1 2 120 000 1 2 1 2 1 2 1 2 1 2 1 2 140 000 1 2 1 2 1 2 1 2 1 2 1 2 160 000 1 2 1 2 1 2 1 2 1 2 1 2 180 000 1 2 1 2 1 2 1 2 1 2 1 2 200 000 1 2 1 2 1 2 1 2 1 2 1 2 300 000 1 2 1 2 1 2 1 2 1 2 3 4 400 000 1 2 1 2 1 2 1 2 1 2 3 4 500 000 1 2 1 2 1 2 3 4 3 4 3 4 600 000 1 2 1 2 3 4 3 4 3 4 3 4 700 000 1 2 3 4 3 4 3 4 3 4 1 800 000 1 2 3 4 3 4 3 4 3 4 1 900 000 1 2 3 4 3 4 3 4 3 4 1 1 000 000 3 ...

Page 46: ...l Size NPT 1 700 000 3 4 1 1 1 1 1 1 4 1 800 000 3 4 1 1 1 1 1 1 4 1 900 000 3 4 1 1 1 1 1 1 4 2 000 000 3 4 1 1 1 1 1 4 1 1 4 2 200 000 3 4 1 1 1 1 4 1 1 4 1 1 4 2 400 000 1 1 1 1 1 4 1 1 4 1 1 2 2 600 000 1 1 1 1 4 1 1 4 1 1 4 1 1 2 2 800 000 1 1 1 1 4 1 1 4 1 1 4 1 1 2 3 000 000 1 1 1 1 4 1 1 4 1 1 4 1 1 2 For L P Gas correct the total Btu hr by multiplying it by 0 6 The answer is the equivalen...

Page 47: ...orifice size must be reduced to ensure complete combus tion Heat input derate of 4 per 1000 feet 305 meters of alti tude above sea level Refer to Table 6 For IEC models consult local gas supplier Gas Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 47 Part No 70532501ENR7 ...

Page 48: ...6 6 001 8 000 1 831 2 440 40 0 0980 2 49 M406361 8 001 10 000 2 441 3 050 42 0 0935 2 37 M403017 U L P Gas 2 001 4 000 610 1 220 41 0 0960 2 44 M401015 4 001 6 000 1 221 1 830 42 0 0935 2 37 M403017 6 001 8 000 1 831 2 440 2 3 mm 0 0906 2 30 70070905 8 001 10 000 2 441 3 050 2 2 mm 0 0866 2 20 70070906 A L P Gas 2 001 4 000 610 1 220 37 0 1040 2 64 M401024 4 001 6 000 1 221 1 830 38 0 1015 2 58 M4...

Page 49: ...17 6 001 8 000 1 831 2 440 32 0 1160 2 95 M402444 8 001 10 000 2 441 3 050 34 0 1110 2 82 M411512 U L P Gas 2 001 4 000 610 1 220 41 0 0960 2 44 M401015 4 001 6 000 1 221 1 830 42 0 0935 2 37 M403017 6 001 8 000 1 831 2 440 2 3 mm 0 0906 2 30 70070905 8 001 10 000 2 441 3 050 2 2 mm 0 0866 2 20 70070906 A L P Gas 2 001 4 000 610 1 220 36 0 1065 2 71 M411375 4 001 6 000 1 221 1 830 37 0 1040 2 64 M...

Page 50: ... 18 M402489 6 001 8 000 1 831 2 440 31 0 1200 3 05 M401017 8 001 10 000 2 441 3 050 32 0 1160 2 95 M402444 U L P Gas 2 001 4 000 610 1 220 38 0 1015 2 58 M411376 4 001 6 000 1 221 1 830 40 0 0980 2 49 M406361 6 001 8 000 1 831 2 440 42 0 0935 2 37 M403017 8 001 10 000 2 441 3 050 2 3 mm 0 0906 2 30 70070905 A L P Gas 2 001 4 000 610 1 220 35 0 1100 2 79 M402487 4 001 6 000 1 221 1 830 36 0 1065 2 ...

Page 51: ...umble dryer as possible If more than one tumble dryer is being installed a circuit breaker must be provided for each NOTE Connect tumble dryer to an individual branch circuit not shared with lighting or other equipment NOTE 3 Phase Tumble Dryers Only Do not use fuses to avoid the possibility of single phasing and caus ing premature failure of the motors WARNING In case of servicing or putting the ...

Page 52: ...on after serv icing W071 For On Premises Laundry OPL Models Only All OPL non vend models are factory equipped with an emer gency stop button on the front panel NOTE Activation of the emergency stop switch stops all tumble dryer control circuit functions but DOES NOT remove all electrical power from tumble dryer Service Ground Location Model Ground and Terminal Block Locations Gas and Steam TMB2450...

Page 53: ...fications below are subject to change without notice Always refer to product serial plate for most current specifications of product being installed CAUTION Use copper conductors only with the following rating when wiring appliance to electric supply Dryer gas and steam heat models require 187 F 75 C mini mum Dryer electric heat models require 194 F 90 C minimum W936 NOTE Connect this appliance to...

Page 54: ...ls Code Voltage Cycle Phase Terminal Block Con nections Re quired Full Load Amps Recommend ed Circuit Breaker Rat ing Amps Wire Size AWG mm2 Q 200 240 50 60 3 L1 L2 L3 and ground 11 15 14 2 5 N 440 480 50 60 3 L1 L2 L3 and ground 6 15 14 2 5 P 380 415 50 60 3 L1 L2 L3 and ground 7 15 14 2 5 Table 9 200 Series Gas and Steam Models Code Voltage Cycle Phase Terminal Block Con nections Re quired Full ...

Page 55: ... 50 60 3 L1 L2 L3 and ground 6 15 14 2 5 P 380 415 50 60 3 L1 L2 L3 and ground 7 15 14 2 5 Table 10 Electrical Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 55 Part No 70532501ENR7 ...

Page 56: ...der to the return In both steam supply and steam return line it is recommended that each have a pipe union and shut off valve This will ena ble you to disconnect the steam connections and service the tumble dryer while your laundry facility is in operation Connect the steam solenoid valve to the related steam coil in let connection with nipples flex hoses unions and tees Strainers may require clea...

Page 57: ... 2 12 in 300 mm Riser 3 Shut Off Valve 4 Condensate Return Line from Supply Line 5 Return 6 Check Valve 7 Vacuum Breaker Optional 8 18 in 460 mm Drop Recommended not above outlet 9 Solenoid Valve Supplied with machine 10 Steam Bonnet 11 Flexible Line 12 Union 13 Trap with Built In Strainer Figure 16 Steam Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 57 Part No 705325...

Page 58: ...ipe Diameter Steam Trap Size Pounds Con densate Hour Kilograms Con densate Hour 80 100 5 3 6 9 1 NPT 345 156 Based on 6 9 bar Table 11 Steam Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 58 Part No 70532501ENR7 ...

Page 59: ...s 1 Risers 12 in 300 mm 2 Shut Off Valve 3 Check Valve 4 Vacuum Breaker optional 5 Condensate Return Line from Supply Line 6 Drop 18 in 460 mm Recommended not above outlet 7 Steam Bonnet 8 Solenoid Valve Supplied with machine 9 Union 10 Trap with Built In Strainer 11 Return 12 Supply Figure 17 Steam Requirements Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 59 Part No 70532501ENR7...

Page 60: ...oid valve traps must be sup ported to minimize loads on the tumble dryer steam coil connections W701R1 Installing Steam Trap and Making Condensate Return Connections The steam trap must be installed and the coil outlet connections must be connected to the condensate return lines The following steps outline the procedure for installing the steam trap and con necting the condensate return lines Refe...

Page 61: ... Opening the shutter increases the amount of primary air supplied to the burner while closing the shutter decreases the primary air supply Adjust air shutter as fol lows Refer to Figure 18 1 Remove the burner inspection hole plate TMB2634N_SVG Figure 18 2 Start the tumble dryer and check the flame pattern If the flame pattern is straight up insufficient air is flowing through the tumble dryer A fl...

Page 62: ...d fan will continue to operate even though the airflow switch is indicating insufficient air flow NOTE To properly mount the airflow switch bracket or in case of a load not drying the airflow switch bracket may need to be checked for proper alignment Be sure the locator pins are securely in their respective holes before tightening the bracket mounting screws This will assure proper alignment of th...

Page 63: ...t is located on rear panel below drive motor If thermostat trips contact a qualified service technician Belt Drive The drive assembly consists of a motor four pulleys two belts idler housing upper belt adjustment jack eyebolt tube lower belt adjustment eyebolt and a spring The pulley diameters are sized to produce a cylinder speed of 37 39 RPM for 120 series models or 29 31 RPM for 170 and 200 ser...

Page 64: ...6 Tighten idler housing mounting screws torque to 50 ft lbs Recheck belt tension 7 Lower belt tension will be affected by adjusting the upper belt tension as it is a dependent system Refer to section below to adjust lower belt Lower Belt Tension 1 Disconnect electrical power to the tumble dryer before at tempting any adjustments to the drive assembly 2 Loosen the right jamnut on the lower belt adj...

Page 65: ... the elec trical outlet and hard or direct wire connections are tight Check the main fuse and circuit breaker Check fuses located in the machine Insufficient airflow Gas shut off valve in OFF position Are controls properly set Broken drive belt Call the service person Tumble dryer is in Cool Down Mode Lint screen clogged Clean lint screen Exhaust duct to outside is blocked Clean out Before You Cal...

Page 66: ...f gas supply external to machine 3 Turn off manual gas shut off valve on machine 4 Turn off steam supply external to machine 5 Remove all electric gas and steam connections Removing Tumble Dryer from Service Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 66 Part No 70532501ENR7 ...

Page 67: ...ment En suring this product is disposed of correctly will help prevent po tential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact the local city office household was...

Page 68: ...e is prepared in accordance with the provisions of SJ T 11364 O Indicates that the content of said hazardous substance in all of the homogenous materials in the component is within the limits required by GB T 26572 X Indicates that the content of said hazardous substance exceeds the limits required by GB T 26572 in at least one homogenous material in the component All parts named in this table wit...

Reviews: