Model
Market
Gas
Altitude
Burner Orifice
feet [meters]
No.
inches
[mm]
Quan-
tity
Part No.
120 Series
T, G, A, H,
J, K, R, U
Natural Gas
2,001-4,000
[610-1,220]
18
0.1695
[4.31]
3
M402988
4,001-6,000
[ 1,221-1,830]
20
0.1610
[4.09]
M401002
6,001-8,000
[ 1,831-2,440]
22
0.1570
[3.99]
M402996
8,001-10,000
[ 2,441-3,050]
25
0.1495
[3.80]
M402997
T, G, H, J,
R
L.P. Gas
2,001-4,000
[610-1,220]
37
0.1040
[2.64]
M401024
4,001-6,000
[ 1,221-1,830]
38
0.1015
[2.58]
M411376
6,001-8,000
[ 1,831-2,440]
40
0.0980
[2.49]
M406361
8,001-10,000
[ 2,441-3,050]
42
0.0935
[2.37]
M403017
U
L.P. Gas
2,001-4,000
[610-1,220]
41
0.0960
[2.44]
M401015
4,001-6,000
[ 1,221-1,830]
42
0.0935
[2.37]
M403017
6,001-8,000
[ 1,831-2,440]
2.3 mm
0.0906
[2.30]
70070905
8,001-10,000
[ 2,441-3,050]
2.2 mm
0.0866
[2.20]
70070906
A
L.P. Gas
2,001-4,000
[610-1,220]
37
0.1040
[2.64]
M401024
4,001-6,000
[ 1,221-1,830]
38
0.1015
[2.58]
M411376
6,001-8,000
[ 1,831-2,440]
40
0.0980
[2.49]
M406361
8,001-10,000
[ 2,441-3,050]
42
0.0935
[2.37]
M403017
Table 6
continues...
Gas Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
48
Part No. 70532501ENR7
Summary of Contents for BA120E