120 Series Electric Models
Code
Voltage
Cycle
Phase
Terminal
Block Con-
nections Re-
quired
Full Load
Amps
Recommend-
ed Circuit
Breaker Rat-
ing Amps
Wire Size
AWG [mm2]
G
230-240
50-60
3
L1, L2, L3
and ground
147
200
3/0 [95]
H
380
50-60
3
L1, L2, L3
and ground
94
125
1 [50]
J
400-415
50-60
3
L1, L2, L3
and ground
86
110
2 [35]
K
440
50-60
3
L1, L2, L3
and ground
82
110
2 [35]
L
460-480
50-60
3
L1, L2, L3
and ground
75
100
3 [26.7]
Table 8
170 Series Gas and Steam Models
Code
Voltage
Cycle
Phase
Terminal
Block Con-
nections Re-
quired
Full Load
Amps
Recommend-
ed Circuit
Breaker Rat-
ing Amps
Wire Size
AWG [mm2]
Q
200-240
50-60
3
L1, L2, L3
and ground
11
15
14 [2.5]
N
440-480
50-60
3
L1, L2, L3
and ground
6
15
14 [2.5]
P
380-415
50-60
3
L1, L2, L3
and ground
7
15
14 [2.5]
Table 9
200 Series Gas and Steam Models
Code
Voltage
Cycle
Phase
Terminal
Block Con-
nections Re-
quired
Full Load
Amps
Recommend-
ed Circuit
Breaker Rat-
ing Amps
Wire Size
AWG [mm2]
Q
200-240
50-60
3
L1, L2, L3
and ground
12
15
14 [2.5]
Table 10
continues...
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
54
Part No. 70532501ENR7
Summary of Contents for BA120E