WARNING
To reduce the risk of severe injury, clearance of tum-
ble dryer cabinet from combustible construction
must conform to the minimum clearances, and/or lo-
cal codes and ordinances.
W770R1
TMB2501N_SVG
4
3
1
5
6
7
8
2
NOTE: Shaded areas indicate adjacent structure.
1.
0.0 in. [0 mm] minimum, 0.5 in. [13 mm] recommended between machines for removal or installation
2.
Allow 2-4 in. [51-100 mm] opening at top of machine to aid in removal or installation. A removable trim piece may be used to
conceal the opening; zero clearance allowed for trim.
3.
4 in. [100 mm] maximum header thickness
4.
Minimum clearance permitted for remainder:
120 Gas/Electric
4.0 in. [100 mm]
120 Steam
12.0 in. [300 mm]
170/200 Gas
4.0 in. [100 mm]
170/200 Steam
12.0 in. [300 mm]
5.
Guard
6.
Provision for make-up air
7.
24 in. [610 mm] minimum, 36 in. [910 mm] recommended for maintenance purposes
8.
0.0 in. [0 mm] minimum, 0.25 in. [6 mm] recommended for removal or installation purposes
Figure 2
Remove Shipping Materials
IMPORTANT: Remove the yellow shipping wire tie se-
curing the airflow switch.
The foam wedge insert for the cylinder should be saved and
MUST be reinstalled whenever the unit is moved. To remove the
foam wedge insert, open the loading door and turn the cylinder
clockwise by using the lifter. The insert will drop into the lint
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
24
Part No. 70532501ENR7
Summary of Contents for BA120E