Exhaust Requirements
Exhaust Requirements
CAUTION
Risk of fire. A clothes dryer produces combustible
lint. Exhaust outdoors. Consult technical instruc-
tions for detailed exhaust specifications.
W933
WARNING
To reduce the risk of fire, DO NOT use plastic or thin
foil ducting to exhaust the tumble dryer.
W773R1
WARNING
To reduce the risk of fire and accumulation of com-
bustible gases, DO NOT exhaust tumble dryer air in-
to a window well, gas vent, chimney or enclosed, un-
ventilated area such as an attic wall, ceiling, crawl
space under a building, or concealed space of a
building.
W059R1
Layout
Whenever possible, install tumble dryers along an outside wall
where duct length can be kept to a minimum, and make-up air
can be easily accessed. Construction must not block the airflow at
the rear of the tumble dryer. Doing so would prevent adequate air
supply to the tumble dryer combustion chamber.
Make-Up Air
A tumble dryer is forced air exhausted and requires provisions for
make-up air to replace air exhausted by tumble dryer.
IMPORTANT: Do not obstruct flow of combustion and
ventilation air.
Required Make-Up Air Opening (to the outside) for
Each Tumble Dryer, in.
2
[cm
2
]
Model
Opening
120 Series
360 [2300]
170 Series
525 [3400]
200 Series
525 [3400]
Make-up air openings with louvers will restrict airflow. The
opening must be increased to compensate for area taken up and
restrictions created by louvers. Contact the louver manufacturer
for the exact specifications.
Make-up air openings in rooms containing tumble dryer(s) and/or
gas fired hot water heater or other gravity vented appliances must
be increased sufficiently to prevent downdrafts in any of the
vents when all tumble dryers are in operation. Do not locate grav-
ity vented appliances between tumble dryer(s) and make-up air
openings. If it is necessary to duct make-up air to tumble dry-
er(s), increase area of duct work by 25% to compensate for re-
strictions in air movement.
Venting
WARNING
To reduce the risk of fire due to increased static
pressure, we do not recommend installation of in-
line secondary lint filters or lint collectors. If secon-
dary systems are mandated, frequently clean the
system to assure safe operation.
W749
IMPORTANT: Installing in-line filters or lint collectors
will cause increased static pressure. Failure to main-
tain the secondary lint system will decrease tumble
dryer efficiency and may void machine warranty.
For maximum efficiency and minimum lint accumulation, tumble
dryer air must be exhausted to the outdoors by the shortest possi-