Gas Category
Country
Gas
Category
Supply Pressure (mbar)
Manifold Pressure (mbar)
nominal
minimum
maximum
II
2L3B/P
RO
G25
2L
20
17
25
12.0
G30
3B/P
30 (28-30)
25
35
*
I
3B/P
IS, MT
G30
3B/P
30 (28-30)
25
35
*
I
2E(R)
BE
G20
2E(R) 20/25
20
17
25
8.0
G25
2E(R) 20/25
20
17
25
12.0
I
3+
BE
G30
3+ (28-30/37)
Butane
30 (28-30)
25
35
*
G31
3+ (28-30/37)
Propane
37
25
45
*
* Appliance regulator out of action
Table 3
Check manifold pressure. It is important that gas be supplied to
the tumble dryer in accordance with the requirements on the seri-
al plate. Refer to table below and
Figure 1
. If the manifold pres-
sure required adjustment, refer to
How to Adjust Gas Valve Gov-
ernor/Regulator
.
CSA Models
AGA Models
CE Models
Natural Gas
3.5 in. w.c.
0.87 kPa
Refer to
Table
3
Propane/
L.P.G.
10.5 in. w.c.
2.61 kPa
The connection of gas supply to the appliance shall be made with
a flexible hose suitable for the appliance category in accordance
with national installation regulations of the country of destina-
tion. If in doubt, the installer shall contact the supplier.
TMB2404N_SVG
6
3
4
5
1
2
1.
Gas Line to Tumble Dryer
2.
Gas Supply Piping System
3.
Gas "T" Fitting
4.
3 in. [76 mm] Minimum Gas Pipe
5.
Gas Pipe Cap
6.
Sediment Trap
Figure 11
Gas Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
39
Part No. 70532501ENR7