Page 1: ...049_03 Instructions for installation use and maintenance 11 2005 AGB 595 WP AGB 596 WP AGB 517 WP AGB 518 WP AGB 512 WP AGB 513 WP GAS FRYERS APPLIANCES WITH MECHANICAL VALVE ...

Page 2: ...ilot light 8 Checking the primary air 8 Checking the functions 8 Note for the installer 8 Running the appliance on other types of gas page 8 Replacing the main burner nozzle 8 Adjusting the pilot burner 9 Adjusting the primary air 9 Maintenance 9 Replacing parts 9 Valve 9 Safety termostat 9 Burner 9 Thermocouple 9 Ignition plug 9 Using the appliance 11 Preparation for use 11 Filling the tank 11 Tu...

Page 3: ... AGB 596 WP 430 300 25 400 15 1 2 GC 1 2 GC 655 800 15 1 2 GC AGB 517 WP AGB 518 WP 1085 875 700 800 1 2 GC 25 400 1 2 GC 1 2 GC 25 208 AGB 512 WP AGB 513 WP 510 300 25 400 15 1 2 GC 1 2 GC 800 15 1 2 GC 700 AGB 595 WP Dimensions ...

Page 4: ...ated on the front of the appliance and on the control panel It contains all necessary reference data such as the name of the manufacturer input pressure gas type setting etc 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 20 II2H3 P mbar 30 37 20 II2H3 P mbar 28 37 20 25 II2L3B P P mbar 30 30 II2ELL3B P P mbar 50 50 20 20 II2E 3 P mbar 28 37 20 25 II2H3B P P mbar 50 50 20 I2E ...

Page 5: ... gas 2H Liquid gas 3 Nozzles Ø 1 100 mm Main burner G20 G30 G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Reference Reference G20 G30 31 20 mbar 28 37 mbar AGB 595 WP AGB 517 WP AGB 512 WP AGB 596 WP AGB 518 WP AGB 513 WP 6 9 6 9 6 9 13 8 13 8 13 8 kW kW kW kW kW kW II2H3 A m3 h kW kW AGB 595 WP AGB 517 WP AGB 512 WP 14 6 9 AGB 596 WP AGB 518 WP AGB 513 WP 28 13 8 0 730 0 540 1 460 1 080 2 x 145 ...

Page 6: ...und the si des and back should be allowed Place table top appliances on a table or shelf in fla me proof material Before connecting up the appliance to the gas sup ply check on the data plate that the appliance is fit ted for the type of gas available If not consult paragraph Running the appliance on other types of gas page 8 Attention When installing the AGB 595 WP and AGB 596 WP models make sure...

Page 7: ...s available locally If not adapt the appliance to the gas family or group required see paragraph Running the ap pliance on other types of gas page 8 To start the appliance up see the instructions for regular use Testing the power rating Use the specific nozzles for the rated output see table 1 in assembly instructions The following are the operating pressure tolerances to ob tain the nominal power...

Page 8: ...pilot light is correctly regulated Draw up a servicing and maintenance contract Note for the installer Explain and demonstrate to the user how the machine works according to the instructions and hand him this manual Remind the user that any structural alterations to the room housing the appliance may affect the combustion air supply Once the alterations have been completed the appliance and its fu...

Page 9: ...rts must be replaced by authorised techni cians only To replace the following parts remove the control panel after unscrewing its fixing screws It is advi sable to empty the tank Valve 1 Fig 2 Unscrew the fitting 3 16 21 17 and loosen the fixing screws The valve may now be removed and replaced with a new one Replace and screw down all parts in the correct order Safety thermostat 11 Fig 3 Unscrew t...

Page 10: ...049 03 Gas fryers 10 AGB 595 WP AGB 512 WP AGB 596 WP AGB 513 WP AGB 517 WP AGB 518 WP 10 11 13 12 11 10 13 10 11 13 12 13 10 11 12 11 10 13 13 12 10 11 3 ...

Page 11: ...the same time press the ignition button 13 Fig 3 Keep the knob pressed down fully for another 15 20 seconds after the pilot burner has lit to allow the thermocouple to heat If the pilot burner goes out repeat the operation The pilot flame may be obser ved through the hole provided for that purpose Lighting the main burner of the tank To ligth the main burner turn the knob to the posi tion required...

Page 12: ...ater whether direct or pressurised Allow the machine to cool down before cleaning Giving the appliance a thorough clean every day after turning it off will keep it in perfect working or der and make it last longer All steel parts should be cleaned with water and a detergent using a damp cloth do not use abrasive substances or corroding detergents Do not use steel wool which could leave traces of r...

Page 13: ...PRODUCT IMPRO VEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...