140
Rockwell Automation Publication 1791ES-UM001G-EN-P - November 2016
Appendix A
Get Diagnostic Status from Modules by Using Explicit Messaging
I/O Assembly and Reference
Data
This section provides information for I/O assembly and reference data.
1791ES Modules
The bits in the tag definitions of the programming software are different than
the bits shown in the following section.
defines the name associations
for clarification with the programming software.
See
for reference data concerning input and output data.
Table 49 - Bit Definitions and Programming Software Tag Names
Bit Definitions
Programming Software Tag Name
Safety Input 0
Pt00Data
Safety Input 15
Pt15Data
Safety Input 0 Status
Pt00InputStatus
Safety Input 15 Status
Pt15InputStatus
Safety In Status
InputStatus
Muting Lamp Status
MutingStatus
Safety Output 0
Pt00Data
Safety Output 7
Pt07Data
Standard Output 0
Test00Data
Standard Output 15
Test15Data
Safety Output 0 Status
Pt00OutputStatus
Safety Output 7 Status
Pt07OutputStatus
Safety Out Status
OutputStatus
Safety Output 0 Monitor
Pt00Readback
Safety Output 7 Monitor
Pt07Readback
Test Output 0 Status
Pt00TestOutputStatus
Test Output 15 Status
Pt15TestOutputStatus
Table 50 - Input Data – 1791ES-IB8XOBV4 Modules
Instance Hex
(decimal)
Connection Type
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
204 (516)
Safety and
standard
0
Safety Input 7
Safety Input 6
Safety Input 5
Safety Input 4
Safety Input 3
Safety Input 2
Safety Input 1
Safety Input 0
224 (548)
Safety and
standard
0
Safety Input 7
Safety Input 6
Safety Input 5
Safety Input 4
Safety Input 3
Safety Input 2
Safety Input 1
Safety Input 0
1
Safety Input 7
Status
Safety Input 6
Status
Safety Input 5
Status
Safety Input 4
Status
Safety Input 3
Status
Safety Input 2
Status
Safety Input 1
Status
Safety Input 0
Status
301 (769)
Only standard
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Output Power
Error
Input Power
Error
324 (804)
Safety and
standard
0
Safety Input 7
Safety Input 6
Safety Input 5
Safety Input 4
Safety Input 3
Safety Input 2
Safety Input 1
Safety Input 0
1
Combined
Safety In Status
Combined
Safety Out
Status
Input Power
Error
(1)
Output Power
Error
Reserved
Reserved
Muting Lamp 7
Status
Muting Lamp 3
Status