Publication 1394-5.0 — May 2000
8-20
Configuring Your 1394 Analog Servo System
[Shunt P]
Shunt resistor continuous power rating.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.
This parameter only needs to be configured
when you are using custom resistors.
Note: [Shunt Type] must be set to "custom shunt"
before making modifications to this shunt
parameter (44-48).
Parameter Numbers
45
Parameter Group
Linear List
Display Units
Watts
Parameter Type
Read/Write
Change While Running
No
Minimum Value
100
Maximum Value
22000
Default Value (22 kW)
900
Default Value (5 and 10 kW
)
200
[Shunt Peak Usage]
This parameter shows the peak usage of the
shunt resistor over the last ten seconds. (%) This
parameter can be observed to determine
proximity of usage to fault condition. Warning is
set at 80%. Fault is set when value reaches
105%.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.
Parameter Numbers
51
Parameter Group
Smart Sys Data
Display Units
%
Parameter Type
Read Only
Linkable
No
[Shunt R]
Shunt resistor resistance. Set this parameter
only when using a custom resistor.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.
Note: [Shunt Type] must be set to "custom shunt"
before making modifications to this shunt
parameter (44-48).
Parameter Numbers
44
Parameter Group
Linear List
Display Units
Ohms
Parameter Type
Read/Write
Change While Running
No
Minimum Value
4 (22kW systems)
16 (5 and 10 kW systems)
Maximum Value
255
Default Value
Set by [Shunt Type]
[Shunt Type]
Selects shunt module model number or type.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.
Note: [Shunt Type] must be set to "custom shunt"
before making modifications to associated shunt
parameters (44-48).
Parameter Numbers
43, 49
Parameter Group
Linear List
Display Units
None
Parameter Type
Read/Write
Change While Running
No
Linkable
No
Default Value
1 "1394-SR-9A"
(22
kW
systems)
6
"Internal" (5 and 10 kW systems)
Selections
0
"Custom Shunt"
1
"1394-SR-9A"
2
"1394-SR-9AF"
3
"1394-SR-36A"
4
"1394-SR-36AF"
5
"1394-SR-10A"
6
"Internal" (5 and 10 kW systems)
[Shunt Usage]
% of shunt power used.
Active on all Smart Power 22 kW systems and 5
and 10 kW (Series C or later) systems.
Parameter Numbers
42
Parameter Group
Smart Sys Data
Display Units
%
Parameter Type
Read Only
Linkable
No
Summary of Contents for 1394 SERCOS
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...