Configuring Your 1394 Analog Servo System
[Language Sel]
Display language for text.
Parameter Numbers
4
Parameter Group
Linear List
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Default Value
0
English
Selections
0
English
[Ld/Lg Degrees]
If [Ld/Lg Freq] and [Ld/Lg Degrees] are set to
non-zero values, a lead/lag filter (one pole, one
zero) is additionally inserted into the feedback
path of the velocity loop. This filter can be used
to enhance the stability of the loop in the
presence of load resonances.
This parameter specifies the amount of phase
shift that occurs at the lead/lag center frequency.
A negative value specifies a lag, while a positive
value specifies a lead.
In most cases, this filter will not be needed.
Parameter Numbers
144, 145, 146, 147
Parameter Group
Vel Loop Tune
Display Units
degs
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
-50 (lag) degs
Maximum Value
+50 (lead) degs
Default Value
0 degs
[Ld/Lg Freq]
This parameter specifies the center frequency of
the lead/lag filter in the velocity feedback path if
employed (see [Ld/Lg Degrees]. If set to zero,
the filter is disabled.
In most cases, this filter will not be needed.
Parameter Numbers
148, 149, 150, 151
Parameter Group
Vel Loop Tune
Display Units
Hz
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Minimum Value
0 Hz
Maximum Value
200 Hz
Default Value
0 Hz
[Line Voltage]
This parameter selects input line voltage being
used. It affects motor velocity ratings and must
be configured prior to selecting motor types.
This value is set automatically in all Smart Power
22 kW systems and 5 and 10 kW (Series C or
later) systems.
Parameter Numbers
9
Parameter Group
Configuration, Setup
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Default Value
0
460 Volts AC
Selections
0
460 Volts AC
1
380 Volts AC
[Max Bandwidth]
After an auto tune, this parameter displays the
maximum system bandwidth that can be
achieved with the machine mechanics.
Parameter Numbers
304, 305, 306, 307
Parameter Group
ATune Config
Display Units
Hz
Parameter Type
Read Only
Linkable
No
Summary of Contents for 1394 SERCOS
Page 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Page 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Page 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Page 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Page 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Page 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Page 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...