![Alcorn Mcbride V+ series User Manual Download Page 184](http://html1.mh-extra.com/html/alcorn-mcbride/v-series/v-series_user-manual_2892709184.webp)
8-10
V16+ Hardware Reference
Connecting a Contact Closure
1.
Locate DIP switches SW17, SW18, SW19, and SW20.
2.
Verify that the appropriate switches are configured for Contact Closures.
3.
Using a Female DB37, attach the appropriate wire from the Input signal pin
(pin 1 for Input1, pin 2 for Input2, etc.) to one of the terminals of the
external contact.
4.
Connect the appropriate Input Return pin to the other terminal of the
external contact (pin 20 for Input1, Pin 21 for Input2, etc.)
Figure 5 – Sample connection for a Contact Closure Input to Input1 of the Parallel
Inputs connector.
Disabling Front Panel Buttons
The V16 provides 16 front panel buttons which duplicate the function of the 16
external inputs. This is convenient for test purposes, but it is often desirable to
prevent the unintentional activation of these signals by the front panel. Any
signals that should not be allowed front panel control should be assigned to
inputs 9 through 16. These front panel switches may be individually disabled
using DIP switch SW21.
Disabling front panel buttons 9-16
1.
For each button to be disabled, move the corresponding switch of SW21 to
the “OFF” position (Switch 1 for Input9, Switch 2 for Input10, etc.)
Summary of Contents for V+ series
Page 2: ...User s Guide To Show Control by Alcorn McBride Inc...
Page 7: ...Third Party Equipment 18 3 Index 19 1...
Page 8: ......
Page 14: ...1 6 Welcome...
Page 28: ...3 14 Show Control Overview GoingToDayModeMsg ClearLine2Msg...
Page 38: ...3 24 Show Control Overview...
Page 82: ...4 44 WinScript User s Guide...
Page 118: ......
Page 144: ...6 26 Advanced WinScript Programming...
Page 170: ...7 26 Application Notes...
Page 220: ...13 8 DMX Machine Hardware Reference...
Page 236: ...14 16 SMPTE Machine Hardware Reference...
Page 254: ...15 18 Appendix A Adding User Defined Serial Protocols...
Page 264: ......