![Alcorn Mcbride V+ series User Manual Download Page 168](http://html1.mh-extra.com/html/alcorn-mcbride/v-series/v-series_user-manual_2892709168.webp)
7-24
Application Notes
WaitingForSelection
waits ten seconds after the Welcome clip finishes
and then restarts the Attract Loop, assuming that the guest has walked
away. If the guest presses a button during the ten-second interval, the
sequence that corresponds with that button will reset
WaitingForSelection
so that it does not restart the Attract Loop.
We provide four separate sequences (triggered individually by a
corresponding pushbutton) to play our informational clips:
GreatRooms
,
GreatRates
,
GreatFood
, and
SpecialOffer
. These sequences check the
status of both flags. If either flag is on, the sequence knows that another clip
is playing and it should not interrupt it, so it does nothing. This forces the
guest to watch a clip in its entirety before choosing another.