Booting 6855 Series Switches
Monitoring the Chassis
OmniSwitch 6855 Series Hardware Users Guide
September 2011
page 5-5
Monitoring the Chassis
OmniSwitch 6855 Series switches can be monitored and managed via the console port using Command
Line Interface (CLI) commands. The switches can also be monitored and managed via the Ethernet using
CLI commands, WebView, SNMP, and OmniVista.
The section below provides some examples of useful hardware-related monitoring CLI commands. Refer
to the
OmniSwitch CLI Reference Guide
for detailed information on all management and monitoring
commands used with the OmniSwitch 6855 Series switch.
Checking the Overall Chassis Status
To check the overall status of a chassis, including the chassis type, and current administrative and opera-
tional status, use the
show chassis
command. For example:
-> show chassis
Chassis 1
Model Name: OS6855-14,
Description: 12 RJ45 + 2 SFP,
Part Number: 902632-90,
Hardware Revision: B07,
Serial Number: H47Q0027,
Manufacture Date: JAN 03 2008,
Admin Status: POWER ON,
Operational Status: UP,
Number Of Resets: 23
MAC Address: 00:e0:b1:6b:ef:30,
For a complete list of output definitions for this command, refer to the
OmniSwitch
CLI Reference Guide
.
Checking the Temperature Status
To check chassis temperature status, including the current temperature and configured threshold values,
use the
show temperature
command. For example:
-> show temperature
Temperature for sensor 1
Hardware Board Temperature (deg C) = 39,
Temperature Upper Threshold Range (deg C) = 14 to 86,
Temperature Upper Threshold (deg C) = 80,
Temperature Status = UNDER THRESHOLD,
Temperature Danger Threshold (deg C) = 86
For a complete list of output definitions for this command, refer to the
OmniSwitch CLI Reference Guide
.