Mounting OS6855-14/P14 and OS6855-U10 Switches Table-Mounting OS6855-14/P14 and OS6855-U10 Switches
OmniSwitch 6855 Series Hardware Users Guide
September 2011
page 4-23
Redundant Chassis Power with PoE (OS6855-14)
For OS6855-14 switches using redundant chassis power
in addition to
PoE, a total of four power supplies
are required.
For this configuration, plug a second Alcatel-Lucent-provided system power supply into the PS2 port on
the rear panel of the chassis.
Next, plug the longer connector cable from one of the Alcatel-Lucent-provided PoE power supplies into
the PoE1 port on the rear panel of the chassis, then connect the shorter connector cable to the female AC
connector on the system power supply installed at step 2.
Plug the longer connector cable from the second PoE power supply into the PoE2 port on the rear panel of
the chassis, then connect the shorter cable to the female AC connector on the remaining system power
supply.
When complete, continue to step 5.
PoE Configurations (OS6855-P14)
OS6855-P14 switches using PoE require a second power supply. This second power supply is a PoE-
specific unit included with your Alcatel-Lucent product shipment and is installed into a separate power
supply tray.
Note.
For OS6855-P14 switches the PoE power supply will be placed in a separate power supply tray.
For this configuration, plug the connector cable from the system power supply into the PS1 port on the
rear panel of the chassis.
Refer to
“PS-I185AC-P (SDR-240-55) Power Supply Mounting” on page 4-14
for mounting instructions.
When complete, continue to step 6.
Redundant Chassis Power with PoE (OS6855-P14)
For OS6855-P14 switches using redundant chassis power
in addition to
PoE, a total of four power
supplies are required.
Note.
For OS6855-P14 switches using redundant chassis power with PoE, place the system power
supplies connected to the PS1 and PS2 ports side-by-side in the tray. The power supplies connected to
ports PoE1 and PoE2 will each be placed in their own separate power supply tray.
For this configuration, plug a second Alcatel-Lucent-provided system power supply into the PS2 port on
the rear panel of the chassis.
Refer to
“PS-I185AC-P (SDR-240-55) Power Supply Mounting” on page 4-14
for mounting instructions.
When complete, continue to step 6.
5
Place the power supply (or supplies) into the power supply tray with the connector cables facing
forward.