LED test
Installation tests
4 - 5 6
365-372-304R7.1
Issue 1, November 2007
............................................................................................................................................................................................................................................................
LED test
Description
This test verifies proper operation of all LEDs on the 1665 DMX circuit packs. Operation
of all the LEDs is necessary to assist in trouble isolation.
Important!
If there are any LED failures, determine if the problem is with the circuit
pack or shelf and replace the faulty unit.
Important!
If the shelf is not fully equipped, move circuit packs around and repeat
the test for all valid circuit pack positions.
LED test procedure
........................................................................................................................................................................................................................
1
Select Fault -> Test -> LED...
........................................................................................................................................................................................................................
2
Choose shelf (1665 DMX).
........................................................................................................................................................................................................................
3
Click Select.
........................................................................................................................................................................................................................
4
Choose Number of Iterations: 1.
........................................................................................................................................................................................................................
5
Click OK.
Result:
All LEDs on the shelf should light for 10 seconds, then extinguish for 10
seconds, and then the proper LEDs will light to indicate the current status of the shelf.
........................................................................................................................................................................................................................
6
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...