Local equipment and cross-connect tests
Installation tests
4 - 1 2
365-372-304R7.1
Issue 1, November 2007
depending on the slot where the DS1 CP is located). Refer to
........................................................................................................................................................................................................................
4
Set the DS1 test set to transmit and receive a Quasi-Random Sequence Signal (QRSS)
with B8ZS formatting.
........................................................................................................................................................................................................................
5
Connect a cable from the DS1 test set
transmit
connection to the IN jack of the DSX-1
associated with the DS1 tributary to be tested (start with the first).
........................................................................................................................................................................................................................
6
Connect a cable from the DS1 test set
receive
connection to the OUT jack of the DSX-1
associated with the DS1 tributary to be tested (start with the first).
Result:
The DS1 test set should indicate it is receiving an error free QRSS signal with
B8ZS formatting.
If an error free signal is not received:
•
Verify that the DS1 line coding format is set to B8ZS using the
View -> Equipment
command
•
Verify that the LBOs are set according to cable length using the
View -> Equipment
.
•
Check DS1 cabling for proper connections.
........................................................................................................................................................................................................................
7
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S
DS1 non-terminating equipment transmission testing (LNW80 switch or LNW59 without optics)
Perform this test when the 1665 DMX is equipped with LNW80 switch packs or LNW59
without optics in the main slots.
Facility loopback testing allows the installer to verify the electrical cabling to the 1665
DMX NE. Follow the procedure below to perform a facility loopback test at the 1665
DMX shelf.
To test cabling to the DSX-1, use a DS1 test set to transmit and receive toward the facility
loopback.
Perform the following tests for each DS1 circuit cabled to the 1665 DMX.
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...