Initial circuit pack installation
Powering and initial circuit pack installation for 1665 Data
Multiplexer (1665 DMX)
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
2 - 2 5
LNW46 (OC-12 OLIU) low-speed installation (optional)
Follow this procedure only if installing LNW46 (OC-12 OLIU) circuit packs into the 1665
DMX High-Capacity shelf.
........................................................................................................................................................................................................................
1
Refer to the engineering job specification. Identify the proper function group(s) and/or
growth slot(s) where LNW46 circuit packs will be installed.
........................................................................................................................................................................................................................
2
Remove the LNW46 or from the packing material.
........................................................................................................................................................................................................................
3
Place the circuit pack into the shelf (slot A1, B1, C1, D1 or G1 as required). Do
NOT
engage the circuit pack in the backplane connector.
........................................................................................................................................................................................................................
4
If a companion circuit pack is required, continue with
. If not, install a blank circuit
pack into the companion circuit pack slot (A2, B2, C2, D2 or G2 as required), then
proceed to
.
Important!
Blank circuit packs are required in all unused slots to provide proper air flow
for cooling.
........................................................................................................................................................................................................................
5
Remove the second LNW46 from the packing material.
........................................................................................................................................................................................................................
6
Place the circuit pack into the shelf (slot A2, B2, C2, D2 or G2 as required).
........................................................................................................................................................................................................................
7
for each additional function group and/or growth slot to be
equipped with LNW46 circuit packs.
........................................................................................................................................................................................................................
8
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S
Summary of Contents for Data Multiplexer Explore 1665
Page 8: ... Contents v i i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 12: ... List of figures x i i 365 372 304R7 1 Issue 1 November 2007 ...
Page 16: ... List of tables x v i 365 372 304R7 1 Issue 1 November 2007 ...
Page 24: ... About this document x x i v 365 372 304R7 1 Issue 1 November 2007 ...
Page 272: ... Final operations Operational tests 5 2 2 365 372 304R7 1 Issue 1 November 2007 ...
Page 326: ... Cleaning pluggable optics modules Fiber cleaning B 1 4 365 372 304R7 1 Issue 1 November 2007 ...
Page 408: ...I N 4 365 372 304R7 1 Issue 1 November 2007 Index ...