OC-48 (low-speed) testing
Installation tests
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
4 - 5 5
........................................................................................................................................................................................................................
12
Verify transmission at the patch panel. There should be no alarms at the test set.
........................................................................................................................................................................................................................
13
Select Fault -> Analysis -> Loopback...
........................................................................................................................................................................................................................
14
Choose the correct port on the OC-48 CP and click Select.
........................................................................................................................................................................................................................
15
Click on Release.
........................................................................................................................................................................................................................
16
Click Apply.
........................................................................................................................................................................................................................
17
Verify loss of transmission at the patch panel. This should be evident by a SONET alarm
and a loss of pattern alarm.
........................................................................................................................................................................................................................
18
Repeat this section for all OC-48 ports.
........................................................................................................................................................................................................................
19
Check off the appropriate box in
Appendix E, “Installation checklist”
.
........................................................................................................................................................
E
N D
O
F
S
T E P S