19
on remote control display. If an outside sensor is connected, you can also
see otside temperature on remote control display. There are wired and wireless
models. In case of using with telephone interface card you can operate combi
boiler from a distance by phone.
3- Phone Control Interface Devices
These devicesenable you to simply turn on/off your combi boiler by your phone.
There are two models, one works with fixed lines and the other with GSM lines.
4- Outside Temperature Sensor
This sensor activates boiler according to the weather conditions. It can be used
either with the controller and thermostats mentioned above or on its own.
All these automatic control devices are optional. For the safety of your boiler,
contact the authorized installers or services to buy any of these options. Do
not forget to ask for user manual of the device. You can get more detailed
information from our web site (www.alarko-carrier.com.tr).
2.9 Automatic Operation of the Boiler in Accordance with
Weather Temperature (Optional)
If you use outside sensor with your boiler, you can manage the appliance with
one of below options:
• In case of “remote cont outside sensor” use, weather compensation
curve is set by the remote controller itself (see remote control installation and
operating manual).
• In case of only outside sensor use, weather compensation curve is set from
parameter menu of electronic card only by authorized services. Parameter
settings are only done by authorized services.
While outside sensor is connected, central heating flow temperature is set
between 30 to 85°C in the systems including radiators. As for floor heating
systems, this range is between 25 to 45°C.
Summary of Contents for SUPER FIT 24
Page 2: ...Code No A 1 5 1i Publishing Date 020321 Revision Date 020321...
Page 8: ...8 1 2 Declaration of Conformity...
Page 23: ...23 3 TECHNICAL CHARACTERISTICS 3 1 Technical Data...
Page 26: ...26 3 4 Dimensions 3 4 Dimensions Figure 7 Dimensions Figure 7 Dimensions Gas Inlet...
Page 35: ...35 Opening the Package Opening the Package Figure 13 Opening the package...
Page 46: ...46 Figure 24 Flue applications...
Page 52: ...52...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...