Do not place the boiler and the propane LPG tubes in the same cabinet.
Use certified tubes only.
Do not shake or lay the tubes.
Only use a certified 30 mbar (300 mmSS) regulator at every tube exit.
The LPG regulator to be supplied must be suitable for the LPG consumption of
the combi model you will use. These consumption values are 1.7, 2.0 and 2.3
kg/h for SUF 24-28-35 models, respectively.
If you smell gas, turn the tubes off and follow the instructions in Gas Safety
section.
WARNING!
The boiler must be adjusted to work with LPG by the Authorized
Service.
The boiler will be out of guarantee unless 30 mbar certified regulators and the
collector kit are used with the boiler.