1.3 Gas Safety

Gas appliances must be installed only by informed and authorized people in 

accordance with rules of local gas distribution institutions. Gas conversion 

processes must also be performed by authorized people. 
This appliance is produced and certified to operate with natural gas or mix LPG 

under gas inlet pressures specified in Section 3.1, Technical Specifications 

Table. Operation under any different gas conditions is not allowed.

Adjusted  gas  type  of  your  boiler  is  written  on  type  label  stuck  in  the  boiler, 

unless it is converted to another gas by an authorized person. Make sure that 

the boiler is not used with a different gas, other than which it is adjusted for or 

it is finally converted to.

1.4 Premix Condensing Technology

With premix technology, i.e. full condensing combi boiler with gas-air pre-mixing 

feature, flue gas temperatures are lowered under 55°C while generating flow 

water temperature at about 50°C and lower thanks to the exchangers with much 

wider heat transfer surface. For flue gas temperatures under 55°C, the water 

vapor inside the flue gas condenses, i.e. transforms to liquid from gas form. 

Thus, energy is captured before going out the flue, and transferred to the water 

inside the exchanger. This is called concealed heat energy. By regeneration of 

energy inside the water vapor, it is possible to save up to %30 from fuel costs. 

Therefore, set the heating temperature to maximum 50°C in order to get 

maximum efficiency from your combi boiler with minimum cost.

As the condensate water is acidic, main exchangers to premix full condensing 

combi boilers shall be made of stainless steel or aluminum alloy resistant to 

acidic condensate water. Alarko Super Fit gas fired combi boilers use main 

exchanger with very high resistance against condensate water.
Combustion is always performed ideally with the premix system, i.e. premixing 

of gas and air at the ideal ratio of 1:10 before combustion. This is ensured by the 

modulating fan which adjusts its speed as per the capacity requirement and the 

venturi which mixes the gas taken by the drawing of the fan from the modulating 

gas valve and air in the ideal ratio.

Summary of Contents for SUPER FIT 24

Page 1: ...90540023 S L KON 27 1 Yayl Hortum Kelep esi 20 5 1103730 58990440126 TS 2500 1 SM 1 DIN 17223 B B Kalite yay eli i 26 1 Yayl Hortum Kelep esi 23 1103729 58990440127 TS 2500 1 SM 1 DIN 17223 B B Kalite...

Page 2: ...Code No A 1 5 1i Publishing Date 020321 Revision Date 020321...

Page 3: ...tart Up 14 2 7 Diagnostics Error Codes 16 2 8 Automatic Control Devices Optional 18 2 9 Automatic Operation of the Boiler In Accordance With Weather Temperature Optional 19 2 11 Solar Connection Set O...

Page 4: ...ections 37 4 6 Appropriate Central Heating Pipes 39 4 7 Gas Connection 40 4 8 Electrical Connections 40 4 9 Flue Connection 43 5 COMMISSIONING THE APPLIANCE 50 6 PERIODIC MAINTENANCE AND CLEANING 50 6...

Page 5: ...f the cable is damaged in any way sw appliance and have the cable replaced by a suitably qualified electrician When replacing the power supply cable only use cables of the same characteristics HO5 VV...

Page 6: ...cs HO5 VV maximum external 8 mm When using an electrical appliance a few fundamental rules must be observed Do not touch the appliance with damp or wet parts of the body or when barefoot Do not pull o...

Page 7: ...The manufacturer will not be held liable for any damage or injury caused as a result of an ineffective or non existent earth system The domestic power supply must be checked by a qualified electricia...

Page 8: ...8 1 2 Declaration of Conformity...

Page 9: ...th much wider heat transfer surface For flue gas temperatures under 55 C the water vapor inside the flue gas condenses i e transforms to liquid from gas form Thus energy is captured before going out t...

Page 10: ...and windows to vent the room CLOSE gas valves of any appliance CLOSE gas valves at the building and apartment inlet DO NOT LIGHT anything and DO NOT SMOKE DO NOT TOUCH electric buttons DO NOT SWITCH f...

Page 11: ...near the boiler Do not place cooker near the appliance and protect the boiler from direct vapor The boiler is to be connected to an earthed 230 V 50 Hz electric supply Toenablethefrostprotectionfuncti...

Page 12: ...Heating Only Off 2 Reset button 3 Heating water temperature decrease button 4 Heating water temperature increase button 5 Domestic hot water DHW temperature increase button 6 Domestic hot water DHW t...

Page 13: ...re 3 Filling operation must last until 1 2 bar value is seen on the manometer Figure 2 If the water pressure falls down under a certain value E04 error is seen on the screen In order to increase the p...

Page 14: ...of the flame is shown with a flame symbol on the display During DHW usage the tap symbol on the display blinks WINTER Mode In order to operate the combi boiler in WINTER mode press key 1 Figure 1 and...

Page 15: ...Section 2 8 If code E04 appears on the display 7 this denotes that there is no water in the boiler Consequently fill the system as described in Section 2 6 Setting Heating CH Temperature The heating...

Page 16: ...error code that is not listed below please call an authorized Service Centre No Flame or Spurious Flame This error code appears if there is no flame ionization current sensed on the burner In this cas...

Page 17: ...t tap to the appliance 3 Open filling tap located under the appliance If filling tap opens in these conditions water in the CH system evacuates from HOT water tap Check pressure value from the manomet...

Page 18: ...ose of comfort and fuel economy 1 On off control devices a Room Thermostat You can use room thermostat with your boiler to maintain desired room temperature Analog and digital wired and wireless model...

Page 19: ...thorized installers or services to buy any of these options Do not forget to ask for user manual of the device You can get more detailed information from our web site www alarko carrier com tr 2 9 Aut...

Page 20: ...ank to the solar connection set which can be supplied as accessory with Super Fit There is no need for any electronic control system Schematics of a working system is shown in Figure 4 solar connectio...

Page 21: ...sends domestic hot water to the combi boiler to be heated to demanded temperature Temperature of domestic hot water coming from combi boiler is also set before being sent to the taps Setting temperat...

Page 22: ...suitable for the LPG consumption of the combi model you will use These consumption values are 1 7 2 0 and 2 3 kg h for SUF 24 28 35 models respectively If you smell gas turn the tubes off and follow t...

Page 23: ...23 3 TECHNICAL CHARACTERISTICS 3 1 Technical Data...

Page 24: ...ation Low temperature regime means 30 C for condensing boilers 37 C for low temperature boilers and 50 C for for other appliances on return temperature Auxiliary electricity consumption Other items Fo...

Page 25: ...ntary heating system Combination Heater Model s SUF 35 Condensing Boiler s Low Temperature Boiler s Yes No No No No Yes Item Symbol Value Unit Item Symbol Value Unit Seasonal space heating energy effi...

Page 26: ...26 3 4 Dimensions 3 4 Dimensions Figure 7 Dimensions Figure 7 Dimensions Gas Inlet...

Page 27: ...OMETER 28 PLASTIC DRAINAGE FITTING S B A 1 3 2 4 3 4 C R 1 2 5 6 7 8 5 6 7 8 9 9 10 10 11 11 12 12 E D F G H I 13 13 14 14 15 15 J K L M N O P 60 1 Gaz Vanas S zd rm 59 1 R Toz K r Tapa M12 58 10 Sac...

Page 28: ...AFETY VALVE 9 AUTOMATIC AIR VENT 10 LIMIT THERMOSTAT 11 HEATING WATER FLOW TEMPERATURE SENSOR 12 PUMP 13 PRESSURE SWITCH 14 FLUE FUSE 15 EXPANSION TANK 16 DOMESTIC HOT WATER DHW TEMPERATURE SENSOR 17...

Page 29: ...ng circulation pump is 0 20 3 7 Circulation Pump Circulation Pump Performance Chart SUF 24 28 Circulation Pump Performance Chart SUF 24 28 Variable Differential Pressure Curve Curve 1 Constant Differe...

Page 30: ...al Pressure Curve Curve 1 Constant Differential Pressure Curve Curve 2 Constant Speed 3 Stages Curve Curve 3 Curve 1 setting Curve 2 setting Curve 3 setting Figure 11 SUF 35 pump performance chart Fig...

Page 31: ...ycle Timed pump overrun function on CH and DHW cycles CH CH antifreeze DHW DHW antifreeze chimney sweeper cycles Anti freeze function on CH and DHW cycles Chimney sweeper function Alternative pump con...

Page 32: ...Icon 3 lights while parameter and service info menu is used Icon 4 Icon 4 lights when flame exists in system Icon 5 Reset When the boiler is switched off at the switch on the control panel the word O...

Page 33: ...6 EU Regulation on appliances burning gaseous fuels 811 2013 Energy labelling of space heaters and combination heaters 813 2013 Ecodesign requirements for space heaters and combination heaters 2014 35...

Page 34: ...4 3 Packaging and Transportation The boiler is packaged in a cardboard box Warning signs are to be observed during transport and storing 4 3 Packaging and Transportation The boiler is packaged in a c...

Page 35: ...35 Opening the Package Opening the Package Figure 13 Opening the package...

Page 36: ...2 Opening the Package 4 4 Installation of the Boiler Figure 23 Opening the package Figure 25 Mounting Instructions 4 4 Installation of the Boiler The appliance must be installed exclusively on a flat...

Page 37: ...der pump Figure 16 see Detail A must be tightened with torque of maximum 18 Nm in case of rubber gasket use This value is 30 Nm in case of cylinder head gasket use To prevent vibration and noise comin...

Page 38: ...here the circuit is frequently topped up or when the system is often either partially or fully drained The outlet connection of the boiler safety valve must be connected to a discharge trap The manufa...

Page 39: ...gen Barrier These systems are not recommended to use In case of use oxygen absorption to underfloor heating system may happen and green colored biocide bacterium may propagate and accumulate as colony...

Page 40: ...for which the appliance has been set up see gas type label inside the boiler The gas supply pressure must be between the values reported on the rating plate see gas type label inside the boiler Prior...

Page 41: ...d by the user if the cable is damaged in any way switch off the appliance and have the cable replaced by a suitably qualified electrician When replacing the power supply cable only use cables of the s...

Page 42: ...oom thermostat connections to terminal board as follows a Switch off the power supply at the main switch b Remove the front case panel of the boiler c Bend the plastic panel holding sheets to the side...

Page 43: ...stions must be taken into consideration for flue installation Horizontal air intake pipes must slope downwards by 3 at the wall towards atmosphere to prevent the entry of rain water dust or impurities...

Page 44: ...cifically designed for condensing boilers Traditional flue components cannot be used for conveying exhaust fumes from condensing boilers nor vice versa Below suggestions must be taken into considerati...

Page 45: ...roof Outlets are close to each other at the same pressure area C33 x Combustion air intake and flue gas discharge with vertical outlet Outlets are close to each other at the same pressure area C43 x C...

Page 46: ...46 Figure 24 Flue applications...

Page 47: ...can be connected directly to the outside or can be connected to a suitable combined flue system MAXIMUM FLUE LENGTH 8 m The maximum flue length linear equivalent is obtained by summing the length of l...

Page 48: ...exhaust gases and draws combustion air through two separate pipes MAXIMUM FLUE LENGTH 80 80 50 m The maximum flue length linear equivalent is obtained by summing the length of linear pipe and the equ...

Page 49: ...ir while the 60 mm plastic inner pipe discharges the exhaust fumes MAXIMUM FLUE LENGTH 8 m The maximum flue length linear equivalent is obtained by summing the length of linear pipe and the equivalent...

Page 50: ...E AND CLEANING 6 1 Periodic Maintenance of the Combi Boiler Authorized Service During and also after guarantee period you must keep taking maintenance once a year before winter to provide safe use fue...

Page 51: ...nsion tank pressure filling if low Control of flue leak proofing Flue gas analysis and combustion control Leakage control of pipe and venturi lines after gas valve with detector or detergent foam Clea...

Page 52: ...52...

Page 53: ...53...

Page 54: ...54...

Page 55: ...55...

Page 56: ...water Operating Pressure bar 6 6 Min Hot water Operating Pressure bar 0 5 0 5 Hot Water Flow Rate t 30 C liter min 11 53 12 25 Dimensions Width mm 410 410 Height mm 730 730 Depth mm 292 5 292 5 Weigh...

Reviews: