17
Limit Thermostat Error
E02
code lights on the display continuously. Call the Service Centre.
Flue Fuse Error
E03
code lights on the display continuously. Call the Service Centre.
Low Water Pressure Error
This error occurs related to the low pressure on heating (CH) system.
If
E04 Low Heating Water Pressure Error
code lights on the display
continuously,
• Check the water pressure in the CH circuit from the manometer.
• Fill the system with water until pressure value reaches to 1.2 bar.
• The boiler will restart automatically. If the problem persists, call the Service
Centre.
There is no error code for excessive water pressure. In such case follow the
instructions below to discharge water from the CH system;
1. Close domestic hot water (DHW) inlet valve under the appliance.
2. Open a HOT water tap in the kitchen or WC (Prefer closest tap to the
appliance)
3. Open filling tap located under the appliance. If filling tap opens in these
conditions, water in the CH system evacuates from HOT water tap. Check
pressure value from the manometer and decrease CH pressure to 1.2 bar.
4. When you see desired pressure value on the manometer; close the hot water
tap, close filling tap on the appliance and open main DHW inlet tap under the
appliance.
Heating Water Flow Tempereature Sensor Error
E05
code lights on the display continuously. Call the Service Centre.
Domestic Hot Water (DHW) Temperature Sensor Error
E06
code lights on the display continuously. Call the Service Centre.
Fan Error
E16
code lights on the display continuously. Call the Service Centre.
Electronic Card Microprocessor Error
E22
code lights on the display continuously. Call the Service Centre.
Remote Control Error
E31
code lights on the display continuously. Check the battery condition
and cable of the remote controller. If the error persists call the Service Centre.
E02
E05
E16
E06
E22
E31
E03
E04
Summary of Contents for SUPER FIT 24
Page 2: ...Code No A 1 5 1i Publishing Date 020321 Revision Date 020321...
Page 8: ...8 1 2 Declaration of Conformity...
Page 23: ...23 3 TECHNICAL CHARACTERISTICS 3 1 Technical Data...
Page 26: ...26 3 4 Dimensions 3 4 Dimensions Figure 7 Dimensions Figure 7 Dimensions Gas Inlet...
Page 35: ...35 Opening the Package Opening the Package Figure 13 Opening the package...
Page 46: ...46 Figure 24 Flue applications...
Page 52: ...52...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...