1. GENERAL INFORMATION

Thank you for choosing ALARKO brand.
This booklet covers ALARKO branded premix condensing Super Fit 24/28/35 

model gas fired combi boilers in, suitable for natural gas or LPG use. Keep this 

booklet on hand to consult to whenever you may need.
You will be informed about combi boiler use by authorized dealers after they 

mount the boiler on its position and set the connections, and by authorized 

service people after they take the boiler into operation. You can ask any unclear 

points again. Our experts will be glad to answer your questions.
For long-term, safe and economical use of the boiler, please read this booklet 

carefully before using the boiler, obey the safety rules and warnings carefully.
Start-up of the boiler by authorized service is free of charge and it is required for 

the product guarantee to be valid. 

1.1 General Notifications

    

Professionally qualified personnel in accordance with current laws 

and standards and in line with the manufacturer’s instructions must 

install the appliance.

     With ‘Professionally qualified personnel’ is intended a personnel with 

technical knowledge in the field of installation and maintenance of 

components for central heating and domestic hot water production 

systems for domestic and industrial use.

     The appliance must be used solely for the purpose for which it has 

been designed and manufactured: central heating and domestic 

hot water production. Any other use is deemed as improper and as 

such dangerous. Under no circumstances will the manufacturer be 

held responsible for damage or injury to persons or animals caused 

by errors in the installation and/or use of the appliance, or through 

non-compliance with current local and national standards and/or the 

manufacturer’s instructions.

     The installation, operation and maintenance manual form an integral 

and essential part of the product and must be kept near the appliance 

always.

     This manual must be kept in a safe place and made available for any 

future reference. If the appliance is sold or transferred to a different 

owner, this must follow the appliance to be read by the new owner 

and/or installer.

21

INSTALLATION INSTRUCTIONS

TA99A086.B0706

15

3.5 Gas connection 

  The connection to the gas supply must be carried out by professionally qualified personnel, registered 

in accordance with current legislation. 

  When connecting the boiler to the gas supply pipe, only use appropriate gas fittings in accordance 

with the Gas Safety and Use Regulations..  

Before installing the boiler, check the following: 

  The pipe work must have a section appropriate for the flow rates requested and the pipe lengths installed, and 

must be fitted with all the safety and control devices provided for by current standards. 

  The gas supply line must be a minimum of a 22mm diameter pipe with an uninterrupted supply from meter to 

boiler and comply with current standards and regulations.  

Check the internal and external seals of the gas supply system. 

  A gas shut-off valve must be installed upstream of the appliance 

  Before starting up the boiler, make sure that the type of gas corresponds to that for which the appliance has 

been set-up (see gas type label inside the boiler). 

  The gas supply pressure must be between the values reported on the rating plate (see gas type label inside the 

boiler). 

  Prior to installation, it is good practice to ensure that there are no machining residues on the gas supply pipe. 

  Conversion of the appliance from natural gas to LPG or vice versa must be carried out by qualified personnel. 

3.6 Electrical connections 

  The connection to the mains power supply must be carried out by professionally qualified personnel, 

registered in accordance with current legislation and authorised by Radiant Bruciatori. 

  Always check to make sure that the appliance has an efficient earth system. This requirement is only 

satisfied if it has been properly connected to an efficient earth system installed in accordance with the 

requirements of current safety standards (Standard CEI 64-8 Electrical Installations).

 This basic safety 

measure must be checked and verified.  

In case of doubt, have the electrical system checked by a qualified electrician. The manufacturer will not be 

held liable for any damage or injury caused as a result of an inefficient or inexistent earth system. 

  The boiler functions with an alternating current of 230 V and 50 Hz and has maximum power absorption of 180 

W. 

The appliance should be protected by a 3 A 

fuse. The connection to the mains electricity supply must be 

via a single-pole switch, with at least 3 millimetres gap between open contacts, mounted upstream of the 

appliance. Make sure that the positions of the live and neutral wires correspond to the wiring diagram. 

  Ensure  the domestic power supply is checked by a qualified electrician to ensure that it can support the 

maximum power absorption of the appliance, as indicated on the rating plate. In particular, make sure that the 

cable sizes are adequate for the power absorbed by the appliance.

  The power supply cable must not be replaced by the user. if the cable is damaged in any way, switch off the 

appliance and have the cable replaced by a suitably qualified electrician.

  When replacing the power supply cable, only use cables of the same characteristics (HO5 VV-F 3x1) with 

maximum external Ø 8 mm;

When using an electrical appliance, a few fundamental rules must be observed: 

  Do not touch the appliance with damp or wet parts of the body or when barefoot. 

  Do not pull on the electric wires. 

  Do not leave the appliance exposed to atmospheric elements (rain, sun, etc,) unless these conditions have been 

expressly provided for. 

  Do not allow the appliance to be used by children or anyone unfamiliar with its operation. 

Alarko Carrier.

3.3 Electrical Connection

110

3.2 Gas Connection

21

INSTALLATION INSTRUCTIONS

TA99A086.B0706

15

3.5 Gas connection 

  The connection to the gas supply must be carried out by professionally qualified personnel, registered 

in accordance with current legislation. 

  When connecting the boiler to the gas supply pipe, only use appropriate gas fittings in accordance 

with the Gas Safety and Use Regulations..  

Before installing the boiler, check the following: 

  The pipe work must have a section appropriate for the flow rates requested and the pipe lengths installed, and 

must be fitted with all the safety and control devices provided for by current standards. 

  The gas supply line must be a minimum of a 22mm diameter pipe with an uninterrupted supply from meter to 

boiler and comply with current standards and regulations.  

Check the internal and external seals of the gas supply system. 

  A gas shut-off valve must be installed upstream of the appliance 

  Before starting up the boiler, make sure that the type of gas corresponds to that for which the appliance has 

been set-up (see gas type label inside the boiler). 

  The gas supply pressure must be between the values reported on the rating plate (see gas type label inside the 

boiler). 

  Prior to installation, it is good practice to ensure that there are no machining residues on the gas supply pipe. 

  Conversion of the appliance from natural gas to LPG or vice versa must be carried out by qualified personnel. 

3.6 Electrical connections 

  The connection to the mains power supply must be carried out by professionally qualified personnel, 

registered in accordance with current legislation and authorised by Radiant Bruciatori. 

  Always check to make sure that the appliance has an efficient earth system. This requirement is only 

satisfied if it has been properly connected to an efficient earth system installed in accordance with the 

requirements of current safety standards (Standard CEI 64-8 Electrical Installations).

 This basic safety 

measure must be checked and verified.  

In case of doubt, have the electrical system checked by a qualified electrician. The manufacturer will not be 

held liable for any damage or injury caused as a result of an inefficient or inexistent earth system. 

  The boiler functions with an alternating current of 230 V and 50 Hz and has maximum power absorption of 180 

W. 

The appliance should be protected by a 3 A 

fuse. The connection to the mains electricity supply must be 

via a single-pole switch, with at least 3 millimetres gap between open contacts, mounted upstream of the 

appliance. Make sure that the positions of the live and neutral wires correspond to the wiring diagram. 

  Ensure  the domestic power supply is checked by a qualified electrician to ensure that it can support the 

maximum power absorption of the appliance, as indicated on the rating plate. In particular, make sure that the 

cable sizes are adequate for the power absorbed by the appliance.

  The power supply cable must not be replaced by the user. if the cable is damaged in any way, switch off the 

appliance and have the cable replaced by a suitably qualified electrician.

  When replacing the power supply cable, only use cables of the same characteristics (HO5 VV-F 3x1) with 

maximum external Ø 8 mm;

When using an electrical appliance, a few fundamental rules must be observed: 

  Do not touch the appliance with damp or wet parts of the body or when barefoot. 

  Do not pull on the electric wires. 

  Do not leave the appliance exposed to atmospheric elements (rain, sun, etc,) unless these conditions have been 

expressly provided for. 

  Do not allow the appliance to be used by children or anyone unfamiliar with its operation. 

Alarko Carrier.

3.3 Electrical Connection

110

3.2 Gas Connection

21

INSTALLATION INSTRUCTIONS

TA99A086.B0706

15

3.5 Gas connection 

  The connection to the gas supply must be carried out by professionally qualified personnel, registered 

in accordance with current legislation. 

  When connecting the boiler to the gas supply pipe, only use appropriate gas fittings in accordance 

with the Gas Safety and Use Regulations..  

Before installing the boiler, check the following: 

  The pipe work must have a section appropriate for the flow rates requested and the pipe lengths installed, and 

must be fitted with all the safety and control devices provided for by current standards. 

  The gas supply line must be a minimum of a 22mm diameter pipe with an uninterrupted supply from meter to 

boiler and comply with current standards and regulations.  

Check the internal and external seals of the gas supply system. 

  A gas shut-off valve must be installed upstream of the appliance 

  Before starting up the boiler, make sure that the type of gas corresponds to that for which the appliance has 

been set-up (see gas type label inside the boiler). 

  The gas supply pressure must be between the values reported on the rating plate (see gas type label inside the 

boiler). 

  Prior to installation, it is good practice to ensure that there are no machining residues on the gas supply pipe. 

  Conversion of the appliance from natural gas to LPG or vice versa must be carried out by qualified personnel. 

3.6 Electrical connections 

  The connection to the mains power supply must be carried out by professionally qualified personnel, 

registered in accordance with current legislation and authorised by Radiant Bruciatori. 

  Always check to make sure that the appliance has an efficient earth system. This requirement is only 

satisfied if it has been properly connected to an efficient earth system installed in accordance with the 

requirements of current safety standards (Standard CEI 64-8 Electrical Installations).

 This basic safety 

measure must be checked and verified.  

In case of doubt, have the electrical system checked by a qualified electrician. The manufacturer will not be 

held liable for any damage or injury caused as a result of an inefficient or inexistent earth system. 

  The boiler functions with an alternating current of 230 V and 50 Hz and has maximum power absorption of 180 

W. 

The appliance should be protected by a 3 A 

fuse. The connection to the mains electricity supply must be 

via a single-pole switch, with at least 3 millimetres gap between open contacts, mounted upstream of the 

appliance. Make sure that the positions of the live and neutral wires correspond to the wiring diagram. 

  Ensure  the domestic power supply is checked by a qualified electrician to ensure that it can support the 

maximum power absorption of the appliance, as indicated on the rating plate. In particular, make sure that the 

cable sizes are adequate for the power absorbed by the appliance.

  The power supply cable must not be replaced by the user. if the cable is damaged in any way, switch off the 

appliance and have the cable replaced by a suitably qualified electrician.

  When replacing the power supply cable, only use cables of the same characteristics (HO5 VV-F 3x1) with 

maximum external Ø 8 mm;

When using an electrical appliance, a few fundamental rules must be observed: 

  Do not touch the appliance with damp or wet parts of the body or when barefoot. 

  Do not pull on the electric wires. 

  Do not leave the appliance exposed to atmospheric elements (rain, sun, etc,) unless these conditions have been 

expressly provided for. 

  Do not allow the appliance to be used by children or anyone unfamiliar with its operation. 

Alarko Carrier.

3.3 Electrical Connection

110

3.2 Gas Connection

21

INSTALLATION INSTRUCTIONS

TA99A086.B0706

15

3.5 Gas connection 

  The connection to the gas supply must be carried out by professionally qualified personnel, registered 

in accordance with current legislation. 

  When connecting the boiler to the gas supply pipe, only use appropriate gas fittings in accordance 

with the Gas Safety and Use Regulations..  

Before installing the boiler, check the following: 

  The pipe work must have a section appropriate for the flow rates requested and the pipe lengths installed, and 

must be fitted with all the safety and control devices provided for by current standards. 

  The gas supply line must be a minimum of a 22mm diameter pipe with an uninterrupted supply from meter to 

boiler and comply with current standards and regulations.  

Check the internal and external seals of the gas supply system. 

  A gas shut-off valve must be installed upstream of the appliance 

  Before starting up the boiler, make sure that the type of gas corresponds to that for which the appliance has 

been set-up (see gas type label inside the boiler). 

  The gas supply pressure must be between the values reported on the rating plate (see gas type label inside the 

boiler). 

  Prior to installation, it is good practice to ensure that there are no machining residues on the gas supply pipe. 

  Conversion of the appliance from natural gas to LPG or vice versa must be carried out by qualified personnel. 

3.6 Electrical connections 

  The connection to the mains power supply must be carried out by professionally qualified personnel, 

registered in accordance with current legislation and authorised by Radiant Bruciatori. 

  Always check to make sure that the appliance has an efficient earth system. This requirement is only 

satisfied if it has been properly connected to an efficient earth system installed in accordance with the 

requirements of current safety standards (Standard CEI 64-8 Electrical Installations).

 This basic safety 

measure must be checked and verified.  

In case of doubt, have the electrical system checked by a qualified electrician. The manufacturer will not be 

held liable for any damage or injury caused as a result of an inefficient or inexistent earth system. 

  The boiler functions with an alternating current of 230 V and 50 Hz and has maximum power absorption of 180 

W. 

The appliance should be protected by a 3 A 

fuse. The connection to the mains electricity supply must be 

via a single-pole switch, with at least 3 millimetres gap between open contacts, mounted upstream of the 

appliance. Make sure that the positions of the live and neutral wires correspond to the wiring diagram. 

  Ensure  the domestic power supply is checked by a qualified electrician to ensure that it can support the 

maximum power absorption of the appliance, as indicated on the rating plate. In particular, make sure that the 

cable sizes are adequate for the power absorbed by the appliance.

  The power supply cable must not be replaced by the user. if the cable is damaged in any way, switch off the 

appliance and have the cable replaced by a suitably qualified electrician.

  When replacing the power supply cable, only use cables of the same characteristics (HO5 VV-F 3x1) with 

maximum external Ø 8 mm;

When using an electrical appliance, a few fundamental rules must be observed: 

  Do not touch the appliance with damp or wet parts of the body or when barefoot. 

  Do not pull on the electric wires. 

  Do not leave the appliance exposed to atmospheric elements (rain, sun, etc,) unless these conditions have been 

expressly provided for. 

  Do not allow the appliance to be used by children or anyone unfamiliar with its operation. 

Alarko Carrier.

3.3 Electrical Connection

110

3.2 Gas Connection

21

INSTALLATION INSTRUCTIONS

TA99A086.B0706

15

3.5 Gas connection 

  The connection to the gas supply must be carried out by professionally qualified personnel, registered 

in accordance with current legislation. 

  When connecting the boiler to the gas supply pipe, only use appropriate gas fittings in accordance 

with the Gas Safety and Use Regulations..  

Before installing the boiler, check the following: 

  The pipe work must have a section appropriate for the flow rates requested and the pipe lengths installed, and 

must be fitted with all the safety and control devices provided for by current standards. 

  The gas supply line must be a minimum of a 22mm diameter pipe with an uninterrupted supply from meter to 

boiler and comply with current standards and regulations.  

Check the internal and external seals of the gas supply system. 

  A gas shut-off valve must be installed upstream of the appliance 

  Before starting up the boiler, make sure that the type of gas corresponds to that for which the appliance has 

been set-up (see gas type label inside the boiler). 

  The gas supply pressure must be between the values reported on the rating plate (see gas type label inside the 

boiler). 

  Prior to installation, it is good practice to ensure that there are no machining residues on the gas supply pipe. 

  Conversion of the appliance from natural gas to LPG or vice versa must be carried out by qualified personnel. 

3.6 Electrical connections 

  The connection to the mains power supply must be carried out by professionally qualified personnel, 

registered in accordance with current legislation and authorised by Radiant Bruciatori. 

  Always check to make sure that the appliance has an efficient earth system. This requirement is only 

satisfied if it has been properly connected to an efficient earth system installed in accordance with the 

requirements of current safety standards (Standard CEI 64-8 Electrical Installations).

 This basic safety 

measure must be checked and verified.  

In case of doubt, have the electrical system checked by a qualified electrician. The manufacturer will not be 

held liable for any damage or injury caused as a result of an inefficient or inexistent earth system. 

  The boiler functions with an alternating current of 230 V and 50 Hz and has maximum power absorption of 180 

W. 

The appliance should be protected by a 3 A 

fuse. The connection to the mains electricity supply must be 

via a single-pole switch, with at least 3 millimetres gap between open contacts, mounted upstream of the 

appliance. Make sure that the positions of the live and neutral wires correspond to the wiring diagram. 

  Ensure  the domestic power supply is checked by a qualified electrician to ensure that it can support the 

maximum power absorption of the appliance, as indicated on the rating plate. In particular, make sure that the 

cable sizes are adequate for the power absorbed by the appliance.

  The power supply cable must not be replaced by the user. if the cable is damaged in any way, switch off the 

appliance and have the cable replaced by a suitably qualified electrician.

  When replacing the power supply cable, only use cables of the same characteristics (HO5 VV-F 3x1) with 

maximum external Ø 8 mm;

When using an electrical appliance, a few fundamental rules must be observed: 

  Do not touch the appliance with damp or wet parts of the body or when barefoot. 

  Do not pull on the electric wires. 

  Do not leave the appliance exposed to atmospheric elements (rain, sun, etc,) unless these conditions have been 

expressly provided for. 

  Do not allow the appliance to be used by children or anyone unfamiliar with its operation. 

Alarko Carrier.

3.3 Electrical Connection

110

3.2 Gas Connection

Summary of Contents for SUPER FIT 24

Page 1: ...90540023 S L KON 27 1 Yayl Hortum Kelep esi 20 5 1103730 58990440126 TS 2500 1 SM 1 DIN 17223 B B Kalite yay eli i 26 1 Yayl Hortum Kelep esi 23 1103729 58990440127 TS 2500 1 SM 1 DIN 17223 B B Kalite...

Page 2: ...Code No A 1 5 1i Publishing Date 020321 Revision Date 020321...

Page 3: ...tart Up 14 2 7 Diagnostics Error Codes 16 2 8 Automatic Control Devices Optional 18 2 9 Automatic Operation of the Boiler In Accordance With Weather Temperature Optional 19 2 11 Solar Connection Set O...

Page 4: ...ections 37 4 6 Appropriate Central Heating Pipes 39 4 7 Gas Connection 40 4 8 Electrical Connections 40 4 9 Flue Connection 43 5 COMMISSIONING THE APPLIANCE 50 6 PERIODIC MAINTENANCE AND CLEANING 50 6...

Page 5: ...f the cable is damaged in any way sw appliance and have the cable replaced by a suitably qualified electrician When replacing the power supply cable only use cables of the same characteristics HO5 VV...

Page 6: ...cs HO5 VV maximum external 8 mm When using an electrical appliance a few fundamental rules must be observed Do not touch the appliance with damp or wet parts of the body or when barefoot Do not pull o...

Page 7: ...The manufacturer will not be held liable for any damage or injury caused as a result of an ineffective or non existent earth system The domestic power supply must be checked by a qualified electricia...

Page 8: ...8 1 2 Declaration of Conformity...

Page 9: ...th much wider heat transfer surface For flue gas temperatures under 55 C the water vapor inside the flue gas condenses i e transforms to liquid from gas form Thus energy is captured before going out t...

Page 10: ...and windows to vent the room CLOSE gas valves of any appliance CLOSE gas valves at the building and apartment inlet DO NOT LIGHT anything and DO NOT SMOKE DO NOT TOUCH electric buttons DO NOT SWITCH f...

Page 11: ...near the boiler Do not place cooker near the appliance and protect the boiler from direct vapor The boiler is to be connected to an earthed 230 V 50 Hz electric supply Toenablethefrostprotectionfuncti...

Page 12: ...Heating Only Off 2 Reset button 3 Heating water temperature decrease button 4 Heating water temperature increase button 5 Domestic hot water DHW temperature increase button 6 Domestic hot water DHW t...

Page 13: ...re 3 Filling operation must last until 1 2 bar value is seen on the manometer Figure 2 If the water pressure falls down under a certain value E04 error is seen on the screen In order to increase the p...

Page 14: ...of the flame is shown with a flame symbol on the display During DHW usage the tap symbol on the display blinks WINTER Mode In order to operate the combi boiler in WINTER mode press key 1 Figure 1 and...

Page 15: ...Section 2 8 If code E04 appears on the display 7 this denotes that there is no water in the boiler Consequently fill the system as described in Section 2 6 Setting Heating CH Temperature The heating...

Page 16: ...error code that is not listed below please call an authorized Service Centre No Flame or Spurious Flame This error code appears if there is no flame ionization current sensed on the burner In this cas...

Page 17: ...t tap to the appliance 3 Open filling tap located under the appliance If filling tap opens in these conditions water in the CH system evacuates from HOT water tap Check pressure value from the manomet...

Page 18: ...ose of comfort and fuel economy 1 On off control devices a Room Thermostat You can use room thermostat with your boiler to maintain desired room temperature Analog and digital wired and wireless model...

Page 19: ...thorized installers or services to buy any of these options Do not forget to ask for user manual of the device You can get more detailed information from our web site www alarko carrier com tr 2 9 Aut...

Page 20: ...ank to the solar connection set which can be supplied as accessory with Super Fit There is no need for any electronic control system Schematics of a working system is shown in Figure 4 solar connectio...

Page 21: ...sends domestic hot water to the combi boiler to be heated to demanded temperature Temperature of domestic hot water coming from combi boiler is also set before being sent to the taps Setting temperat...

Page 22: ...suitable for the LPG consumption of the combi model you will use These consumption values are 1 7 2 0 and 2 3 kg h for SUF 24 28 35 models respectively If you smell gas turn the tubes off and follow t...

Page 23: ...23 3 TECHNICAL CHARACTERISTICS 3 1 Technical Data...

Page 24: ...ation Low temperature regime means 30 C for condensing boilers 37 C for low temperature boilers and 50 C for for other appliances on return temperature Auxiliary electricity consumption Other items Fo...

Page 25: ...ntary heating system Combination Heater Model s SUF 35 Condensing Boiler s Low Temperature Boiler s Yes No No No No Yes Item Symbol Value Unit Item Symbol Value Unit Seasonal space heating energy effi...

Page 26: ...26 3 4 Dimensions 3 4 Dimensions Figure 7 Dimensions Figure 7 Dimensions Gas Inlet...

Page 27: ...OMETER 28 PLASTIC DRAINAGE FITTING S B A 1 3 2 4 3 4 C R 1 2 5 6 7 8 5 6 7 8 9 9 10 10 11 11 12 12 E D F G H I 13 13 14 14 15 15 J K L M N O P 60 1 Gaz Vanas S zd rm 59 1 R Toz K r Tapa M12 58 10 Sac...

Page 28: ...AFETY VALVE 9 AUTOMATIC AIR VENT 10 LIMIT THERMOSTAT 11 HEATING WATER FLOW TEMPERATURE SENSOR 12 PUMP 13 PRESSURE SWITCH 14 FLUE FUSE 15 EXPANSION TANK 16 DOMESTIC HOT WATER DHW TEMPERATURE SENSOR 17...

Page 29: ...ng circulation pump is 0 20 3 7 Circulation Pump Circulation Pump Performance Chart SUF 24 28 Circulation Pump Performance Chart SUF 24 28 Variable Differential Pressure Curve Curve 1 Constant Differe...

Page 30: ...al Pressure Curve Curve 1 Constant Differential Pressure Curve Curve 2 Constant Speed 3 Stages Curve Curve 3 Curve 1 setting Curve 2 setting Curve 3 setting Figure 11 SUF 35 pump performance chart Fig...

Page 31: ...ycle Timed pump overrun function on CH and DHW cycles CH CH antifreeze DHW DHW antifreeze chimney sweeper cycles Anti freeze function on CH and DHW cycles Chimney sweeper function Alternative pump con...

Page 32: ...Icon 3 lights while parameter and service info menu is used Icon 4 Icon 4 lights when flame exists in system Icon 5 Reset When the boiler is switched off at the switch on the control panel the word O...

Page 33: ...6 EU Regulation on appliances burning gaseous fuels 811 2013 Energy labelling of space heaters and combination heaters 813 2013 Ecodesign requirements for space heaters and combination heaters 2014 35...

Page 34: ...4 3 Packaging and Transportation The boiler is packaged in a cardboard box Warning signs are to be observed during transport and storing 4 3 Packaging and Transportation The boiler is packaged in a c...

Page 35: ...35 Opening the Package Opening the Package Figure 13 Opening the package...

Page 36: ...2 Opening the Package 4 4 Installation of the Boiler Figure 23 Opening the package Figure 25 Mounting Instructions 4 4 Installation of the Boiler The appliance must be installed exclusively on a flat...

Page 37: ...der pump Figure 16 see Detail A must be tightened with torque of maximum 18 Nm in case of rubber gasket use This value is 30 Nm in case of cylinder head gasket use To prevent vibration and noise comin...

Page 38: ...here the circuit is frequently topped up or when the system is often either partially or fully drained The outlet connection of the boiler safety valve must be connected to a discharge trap The manufa...

Page 39: ...gen Barrier These systems are not recommended to use In case of use oxygen absorption to underfloor heating system may happen and green colored biocide bacterium may propagate and accumulate as colony...

Page 40: ...for which the appliance has been set up see gas type label inside the boiler The gas supply pressure must be between the values reported on the rating plate see gas type label inside the boiler Prior...

Page 41: ...d by the user if the cable is damaged in any way switch off the appliance and have the cable replaced by a suitably qualified electrician When replacing the power supply cable only use cables of the s...

Page 42: ...oom thermostat connections to terminal board as follows a Switch off the power supply at the main switch b Remove the front case panel of the boiler c Bend the plastic panel holding sheets to the side...

Page 43: ...stions must be taken into consideration for flue installation Horizontal air intake pipes must slope downwards by 3 at the wall towards atmosphere to prevent the entry of rain water dust or impurities...

Page 44: ...cifically designed for condensing boilers Traditional flue components cannot be used for conveying exhaust fumes from condensing boilers nor vice versa Below suggestions must be taken into considerati...

Page 45: ...roof Outlets are close to each other at the same pressure area C33 x Combustion air intake and flue gas discharge with vertical outlet Outlets are close to each other at the same pressure area C43 x C...

Page 46: ...46 Figure 24 Flue applications...

Page 47: ...can be connected directly to the outside or can be connected to a suitable combined flue system MAXIMUM FLUE LENGTH 8 m The maximum flue length linear equivalent is obtained by summing the length of l...

Page 48: ...exhaust gases and draws combustion air through two separate pipes MAXIMUM FLUE LENGTH 80 80 50 m The maximum flue length linear equivalent is obtained by summing the length of linear pipe and the equ...

Page 49: ...ir while the 60 mm plastic inner pipe discharges the exhaust fumes MAXIMUM FLUE LENGTH 8 m The maximum flue length linear equivalent is obtained by summing the length of linear pipe and the equivalent...

Page 50: ...E AND CLEANING 6 1 Periodic Maintenance of the Combi Boiler Authorized Service During and also after guarantee period you must keep taking maintenance once a year before winter to provide safe use fue...

Page 51: ...nsion tank pressure filling if low Control of flue leak proofing Flue gas analysis and combustion control Leakage control of pipe and venturi lines after gas valve with detector or detergent foam Clea...

Page 52: ...52...

Page 53: ...53...

Page 54: ...54...

Page 55: ...55...

Page 56: ...water Operating Pressure bar 6 6 Min Hot water Operating Pressure bar 0 5 0 5 Hot Water Flow Rate t 30 C liter min 11 53 12 25 Dimensions Width mm 410 410 Height mm 730 730 Depth mm 292 5 292 5 Weigh...