ATTENTION!
When the device is switched on and after every power failure, the venting
function works for safe operation. The venting function takes about 3
minutes and “PnP run” appears on the display during this period.
When display backlight is off, pushing key number (
5
) or (
6
) once leads to
backlight turning on and to set temperature value to be shown on the display.
5 seconds later backlight turns off and the display keeps showing the instant
temperature.
2.7 Diagnostics – Error Codes
This paragraph contains a list of error codes that the boiler may generate on
the display (
7
) (See Figure 1) together with the relative indications and the
operations that the user can carry out to reset the boiler.
If the problem re-occurs after the following actions have been taken or
if you see another error code that is not listed below, please call an authorized
Service Centre.
No Flame or Spurious Flame
This error code appears if there is no flame (ionization current) sensed on the
burner. In this case code
E01
lights on the display continuously.
• Check that the gas valve on the boiler and gas meter are open and make
sure that there is gas in the mains supply (or in the tank).
• Turn off and then turn on the appliance using button (
1
) (Figure 1) on the
control panel. Let the system ignite by itself, if
E01
error remains, retry to turn
off and turn on the appliance once again. This action is taken in order to be
sure if the gas in the pipes reached to the appliance.
• When the error code on the display disappears, the boiler will restart. If the
problem persists, call the Service Centre.
This error may occur on the appliances in which gas supply is cut off for long
time period. In general, when gas is supplied to the appliance and after some
number of ignition trials, system starts by itself.
E01
Summary of Contents for SUPER FIT 24
Page 2: ...Code No A 1 5 1i Publishing Date 020321 Revision Date 020321...
Page 8: ...8 1 2 Declaration of Conformity...
Page 23: ...23 3 TECHNICAL CHARACTERISTICS 3 1 Technical Data...
Page 26: ...26 3 4 Dimensions 3 4 Dimensions Figure 7 Dimensions Figure 7 Dimensions Gas Inlet...
Page 35: ...35 Opening the Package Opening the Package Figure 13 Opening the package...
Page 46: ...46 Figure 24 Flue applications...
Page 52: ...52...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...