Introduction to Wiring
©Aqua-Hot®
600D Installation Manual
p. 30
Wiring the Aqua-Hot
This section will introduce the basic considerations,
practices, and information necessary to wire the Aqua-Hot to
any relevant coach-side systems.
\
J8 Plug:
The J8 plug is responsible for connections that pertain to
sensor monitoring within the coach, and is standardized across
all Reporter-bearing Aqua-Hot heating systems.
Pin
Number
Description
Wire No.
J8-1
Low-Level Sensor Input
16
J8-2
Low-Temp Sensor Input
10
J8-3
Tank Temp Sensor/Control
Thermostat
14
J8-4
Low-Level Power Supply (12V DC+)
15
J8-5
Low-Temp Power Supply (12V DC+)
9
J8-6
Tank Temp Sensor/Control
Thermostat
13
Installation must be performed by a professional installer
or technician as per national/local regulations.
Improper installation can cause property damage, injury, or
death.
Figure 54
NOTE:
Reference the Schematics starting on page
47 for more information.
J8 Wire Insertion View Shown
6
5
4
3
2
1
J1 Plug:
The J1 plug manages heating
zone inputs from the coach.
Heating Zone 1 is reserved
electrically for the “Bedroom
Heating Zone” (Heating Loop
1) ONLY. Heating zones 2, 3, &
4 are reserved electrically for
the “Bathroom and Fresh Water
Tank Heating Zone” (Heating
Loop 2) ONLY.
Heating Zone 5 is reserved for the “Living Room and Kitchen
Heating Zone” (Heating Loop 3) ONLY.
See pin-out information below.
Pin
Number
Description
Wire No.
J1-1
Diesel Input
51
J1-2
Electric Low Input
53
J1-3
Electric High Input
40
J1-4
Engine Preheat Input
55
J1-5
Zone 1 Input
95
J1-6
Zone 2 Input
91
J1-7
Zone 3 Input
87
J1-8
Zone 4 Input
86
J1-9
Zone 5 Input (Optional)
79
9
8
7
6
5
4
3
2
1
J1 Wire insertion view shown
Figure 55
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
Summary of Contents for Aqua-Hot 600 Series
Page 1: ...Installation Manual 600Series AHE 600 D04 with...
Page 50: ...Purging the Heating Loop Aqua Hot 600D Installation Manual p 49 System Schematics SWITCH PANEL...
Page 51: ...System Schematics Aqua Hot 600D Installation Manual p 50 HEAT EXCHANGERS...
Page 52: ...System Schematics Aqua Hot 600D Installation Manual p 51 HEATING ZONE THERMOSTATS...