Providing DC Power
©Aqua-Hot®
600D Installation Manual
p. 38
Connecting the 600D to 12V DC Power
This section will outline the requirements, steps, and
information necessary to connect the Aqua-Hot to the vehicle’s
12V DC power system. Follow all guidelines and pay attention to
all notes contained herein. Failure to adhere to these guidelines
can inhibit unit performance, and may cause damage to the
Aqua-Hot and/or the coach.
The Aqua-Hot is designed to shut down in the event that
the DC voltage level drops too low to properly operate. It is
imperative that the proper wire gauge be determined and
utilized. Reference Page 45 for proper wire gauge sizing. Please
not that under full-load conditions, the Aqua-Hot can draw as
much as 20 amps of DC current.
• Installation must be performed by a qualifi ed, professional
according to current national regulations. Reference
A119.2/NFPA 501C Standard on Recreational Vehicles
1993 Edition for relevant national regulatory information.
• Select the correct wire gauge for installation referencing
ANSI/RVIA-LV.
• Protect the Aqua-Hot from over-current and shorting by
incorporating a 20A breaker (minimum) to the Aqua-Hot’s
coach-side power connection.
• The 12-volt supply to the heater must be routed directly
from the battery.
• All power circuits must be protected with fuses or automatic
circuit breakers.
• Reference the schematics starting on Page 46 and Figure
76.
• The image below is simply a reference. A professional,
licensed installer needs to determine the necessary
components and confi guration according to local codes
and standards.
Instructions:
1. Run and connect two wires, one red wire (+ power) and
one black wire (- ground) from the vehicle’s main battery
disconnect to the Aqua-Hot’s Reporter.
2. Label the wires indicating whether they are a power or
a ground wire.
3. Attach the DC power wires onto the appropriate
connections on the Reporter.
4. Connect both power and ground wires to the vehicle’s
battery through the vehicle’s main battery disconnect.
Figure 76
Negative/Ground
Positive/Power
In-Line
Fuse
Main Battery
Disconnect
+
-
DO NOT connect 12V DC power to the Aqua-Hot
if the vehicle requires welding. Electrical welding
will cause serious, irreversible damage to the
Aqua-Hot.
Do NOT activate the diesel burner until the antifreeze and
water heating solution has been added to the boiler tank and
the heating system has been completely bled of air. Operating
the Aqua-Hot without the heating solution will cause serious
damage to the Aqua-Hot’s boiler tank.
Summary of Contents for Aqua-Hot 600 Series
Page 1: ...Installation Manual 600Series AHE 600 D04 with...
Page 50: ...Purging the Heating Loop Aqua Hot 600D Installation Manual p 49 System Schematics SWITCH PANEL...
Page 51: ...System Schematics Aqua Hot 600D Installation Manual p 50 HEAT EXCHANGERS...
Page 52: ...System Schematics Aqua Hot 600D Installation Manual p 51 HEATING ZONE THERMOSTATS...