Introduction to Wiring
©Aqua-Hot®
600D Installation Manual
p. 31
J7 Plug:
The J7 plug manages zone fans and the burner switch indicator
light..
Pin No.
Description
Wire No.
J7-6
Burner Indicator Light Ground
57
J7-3
Burner Indicator Light
56
J7-12
Zone Fan 1 (Switched 12V+)
92
J7-9
Zone Fan 1 Ground
93
J7-2
Zone Zan 2 (Switched 12V+)
88
J7-5
Zone Fan 2 Ground
77
J7-11
Zone Zan 3 (Switched 12V+)
84
J7-8
Zone Fan 3 Ground
85
J7-1
Zone Zan 4 (Switched 12V+)
80
J7-4
Zone Fan 4 Ground
81
J7-10
Zone Fan 5 (Switched 12V+)
76
J7-7
Zone Fan 5 Ground
78
Figure 57
Figure 56
Wire Insertion View Shown
12
11
10
9
8
7
6
5
4
3
2
1
ZONE
1
ZONE
2
ZONE
3
ZONE
4
ZONE
5
J9
The J9 plug is an optional use terminal
that provides constant 12V DC current to any
attachments which may be added to the coach.
J9 Pin No.
J9-1
J9-2
J9-3
J9-4
J9-5
J9-6
J9-7
J9-8
Description
Engine Preheat
Electric
Diesel 12V DC Switch
Zone 5 Thermostat
Zone 4 Thermostat
Zone 3 Thermostat
Zone 2 Thermostat
Zone 1 Thermostat
Wire No.
54
52
50
78
82
86
90
94
Wire Insertion View Shown
8
7
6
5
4
3
2
1
ZONE 5
ZONE 4
ZONE 3
ZONE 2
ZONE 1
Summary of Contents for Aqua-Hot 600 Series
Page 1: ...Installation Manual 600Series AHE 600 D04 with...
Page 50: ...Purging the Heating Loop Aqua Hot 600D Installation Manual p 49 System Schematics SWITCH PANEL...
Page 51: ...System Schematics Aqua Hot 600D Installation Manual p 50 HEAT EXCHANGERS...
Page 52: ...System Schematics Aqua Hot 600D Installation Manual p 51 HEATING ZONE THERMOSTATS...