Confi guring the Zones
©Aqua-Hot®
600D Installation Manual
p. 37
Manual Mode
LED Activity
Status
Solid Green
Reporter is connected to
network and communicating
properly
OFF
Reporter has no power, or
has failed completely
Solid Red
Reporter has gone offl ine
and is not connected to
network
Flashing Green
(4/second)
Reporter is attempting to
make an initial connection to
the network
Flashing Green
(1/second)
The Reporter is online, but
it has not received a valid
network message for at least
5 seconds
Alternating Red and
Orange
Reporter has gone offl ine
and is attempting to re-con-
nect (within 30 seconds)
Alternating Green
and Orange
Reporter is currently online
but has gone offl ine 2 or
more times.
RV-C Network Connectivity
The Reporter was designed to interface with the coach-side
RV-C network to aid in the Aqua-Hot’s integration into the on-
board RV-C network.
There is an indicator light on the back of the Reporter which
shows the current status of the Reporter’s connection to the
RV-C network. This will be useful when diagnosing potential
problems with the coach-side RV-C network.
This mode can accessed under the test page of the Aqua-Hot
Reporter (see below).
Once the test page is open, select the MANUAL MODE and
select “NEXT”. Manual mode will continue to run for up to 3
days without any user intervention. Pressing the reset button
at any time while enabled will reset the timer, and run for an
additional 3 days.
All heating zones are linked together and can be run at 25%,
50%, 75%, and 100% (as shown below). The burner and electric
can be enabled or disabled. For all levels, there is a 10 minute
duty cycle period that will allow Cozy fans to be on for the
specifi ed percentage of 10 minutes. Example, 25% would be on
for 2.5 minutes, and then off for 7.5 minutes. It always starts
with the on-cycle, then shuts off for the remainder of the 10
minute period.
If the system power is cycled, the manual mode will be disabled
and must be manually reactivated. Leaving the manual mode
page will also disable manual mode and restore normal
operation. Leaving manual mode should be done once the
system failure has been resolved and normal operation can
resume.
NOTE:
If using the rocker switches, burner & electric switches
must be toggled on/off after leaving Manual Mode.
Figure 73
Figure 74
Figure 75
Manual Mode
The 2.0 Reporters with CFG 1.9 and greater come with a manual
mode in case the general coach RV-C network fails. It will allow
for limited operation while the larger network/module problem
is addressed.
To determine the version of Reporter, the Reporter 2.0 modules
are shipped with version decals affi xed to the back of the circuit
board, OR shown on the home screen - “FW: 2.0”.
NOTE:
On the 600/675 units, the electric element can be
operated in low or high modes.
Summary of Contents for Aqua-Hot 600 Series
Page 1: ...Installation Manual 600Series AHE 600 D04 with...
Page 50: ...Purging the Heating Loop Aqua Hot 600D Installation Manual p 49 System Schematics SWITCH PANEL...
Page 51: ...System Schematics Aqua Hot 600D Installation Manual p 50 HEAT EXCHANGERS...
Page 52: ...System Schematics Aqua Hot 600D Installation Manual p 51 HEATING ZONE THERMOSTATS...