Confi guring the Zones
©Aqua-Hot®
600D Installation Manual
p. 35
Aqua-Hot Reporter
Boost Pumps
Boost pump functionality has changed with the
implementation of the Reporter 2.0.
On Reporter 1.0 units, any boost pumps at use within the
coach required a relay connected to wires 3b and 5b in order
to operate.
With Reporter 2.0, that relay can now be eliminated, with
boost pump power and functionality now being handled directly
by the Reporter. Using a fl ag-terminal, connect the boost pump
directly to the harness bearing in mind the requirements below.
• Zone 1: Connect to Wire 5b
Max Current Draw:
5.0A
Over-Current Condition:
8.0A
• Zone 2: Connect to Wire 3b
Max Current Draw:
3.0A
Over-Current Condition:
5.0A
Original Equipment Manufacturers (OEMs) will need to
provide the ground for operating boost pumps from the Reporter.
Electrical Specifi cations:
The Reporter contains a single Amphenol ATP family
connector that serves as the power connection to the coach
side 12V DC power system. Mating connection components
are not supplied by Aqua-Hot. Compatible part numbers and
manufacturers are supplied below. The Reporter must be
operated to the below listed specifi cations.
Minimum Voltage.....................................11.0V DC
Maximum Voltage....................................15.0 V DC
Minimum Current.....................................75mA
Maximum Current....................................15A
Please note that the minimum current rating is the minimum
requirement for what will operate the Reporter. Operating
at this current rating will not provide suffi cient power to any
components dependent upon the Reporter.
Input Load currents
Zone Thermostats (each)..................................appx. 1mA
Diesel Burner Switch........................................ appx. 1mA
Electric Element Switch.................................... appx. 1mA
Low-Level Cutoff Switch.................................... appx. 1mA
Control Thermostat (Reporter 1.0)................... appx. 1mA
Tank Temperature Sensor (Reporter 2.0)........ appx. 1mA
Low-Temperature Cutoff Thermostat................ appx. 1mA
Output Load currents
Zone Fans (Reporter 1.0/all).................................3.0A max
Zone Fan 1 (Reporter 2.0)......................................8.0A max
Zone Fans 2-5 (Reporter 2.0).................................5.0A max
Zone Fans (all)......................................................0.25A max
Circulation Pumps (each).......................................2.0A max
AC Relay..................................................................0.5A max
Burner Power..........................................................6.0A max
RV-C Mating Connection
Mfg.
Part Number
Description
3M
37104-A165-OOE-MB
RV-C Connection Housing
Reporter Power Connection
Pins
Housing
Wedge
Deuthsche
Amphenol
1060-12-0222
AT60-12-0222
DTP04-2P
ATP04-2P
WP-2P
AWP-2P
Mfg.
TE
TE
3M
TE
TE
TE
Harness Connections
Mate
J1
J2
J3
J7
J8
J9
Part Number
Description
1-480706-0
09P UMNL Plug
1-480710-0
15P UMNL Plug
37104-2165-000 FL
100
CONN Plug 2MM 4POS
20-22 AWG
1-480708-0
12P UMNL Plug
1-480704-0
06P UMNL Plug
640582-1
08P UMNL Plug
Mfg.
Mate
TE
J1
J2
J3
J7
J8
J0
Sockets
Part Number
Description
350550-1
UMNL SOK 20-14
TIN/PHBZ L/P
Mfg.
TE
Part Number
Socket Crimping Tool
90547-1
Description
ASSY Pro-Crimper M-N-L
Burner Master Control............................................2.0A max
Burner Thermostat Control....................................1.0A max
Connection Terminal Information
Summary of Contents for Aqua-Hot 600 Series
Page 1: ...Installation Manual 600Series AHE 600 D04 with...
Page 50: ...Purging the Heating Loop Aqua Hot 600D Installation Manual p 49 System Schematics SWITCH PANEL...
Page 51: ...System Schematics Aqua Hot 600D Installation Manual p 50 HEAT EXCHANGERS...
Page 52: ...System Schematics Aqua Hot 600D Installation Manual p 51 HEATING ZONE THERMOSTATS...