Appendix
©Aqua-Hot®
600D Installation Manual
p. 54
Measuring Antifreeze
Properly Apply Antifreeze to the Prism Assembly
Use the guide below to properly apply the propylene glycol
mixture to the prism assembly of the refractometer. Once that
is complete, peer through the eyeglass of the refractometer to
continue to the next step.
Adjust the Boundary Line
Once the glycol solution has been properly applied, adjust the
calibration screw until the boundary line labeled “Propylene
Glycol” is set to 32°F. The graphic to the right has been designed
as an aid, but note that it may differ from what is shown in the
refractometer sight glass.
Application of Propylene Glycol
Poor
Poor
Good
Boundary Line
Adjust to 32°F
Lower White Field
Upper Blue Field
Refractometer Sight Glass
Measuring Antifreeze Using a Refractometer
Eye Piece
Prism Assembly
Daylight Plate
Assembly
Calibration Screw