System Features
©Aqua-Hot®
600D Installation Manual
p. 4
System Specifi cations
Diesel Burner
Heat Input (Firing Rate) ....................................... 56,000 BTU/hr
Fuel Consumption ....................................................... 0.41 gal/hr
Electric Element
Power Consumption ....................................................(2) 2000 W
Voltage ............................................................. 120V AC / 12V DC
DC Power
Consumption ...................................................184 W (maximum)
Zone Heat Circulation
Pumps ...........................................................................................3
Power Consumption (max) .........................................21 W (each)
Voltage ............................................................................... 12V DC
Heating Zones
Maximum ............................................. 5 (max) + Engine Preheat
Domestic Water Heating
Maximum .....................................................2.0 GPM On-demand
Physical Specifi cations
Dimensions (US)............................18.5” H x 18.5” W x 36.75” L
Dry Weight ......................................................................... 186lbs.
Wet Weight ......................................................................... 303lbs.
All vehicle installations must comply with the requirements listed in
the Recreational Vehicle Industry Association’s (RVIA) ANSI/NFPA
1192 Handbook for Recreational Vehicle Standards. To receive a
copy of this handbook and other Pertinent RVIA Standards, write to:
Recreation Vehicle Industry Association, 1896 Preston White Drive,
PO Box 2999, Reston, VA 22090-0999. Call them at (703) 620-
6003 or visit online at www.rvia.org.
NOTE:
This product label is attached to the top of the Aqua-
Hot, and provides a ready reference to specifi cations, test
standards, and important safety notices.
Figure 2
Figure 3
Summary of Contents for Aqua-Hot 600 Series
Page 1: ...Installation Manual 600Series AHE 600 D04 with...
Page 50: ...Purging the Heating Loop Aqua Hot 600D Installation Manual p 49 System Schematics SWITCH PANEL...
Page 51: ...System Schematics Aqua Hot 600D Installation Manual p 50 HEAT EXCHANGERS...
Page 52: ...System Schematics Aqua Hot 600D Installation Manual p 51 HEATING ZONE THERMOSTATS...