Version May 2021
EN
27
agru SP 63 mobile
V 3
User’s Manual
agru Kunststofftechnik GmbH
Ing.-Pesendorfer-Str. 31
4540 Bad Hall, Austria
5
Printing Pipe Labels and Downloading Welding Reports
The machine is equipped with USB A interface that gives you the op-
portunity to connect the tag printer or a USB stick. The interface port
correspond to the USB version 2.0 specification (i. e., maximum com-
muncation rate of 480 megabits per second).
5.1 Downloading Welding Reports to a USB Stick
When a USB stick is connected to the interface port while the standard
home screen (see Display 3) is showing, the machine displays the menu
in which the file type can be selected that is going to be used for down-
loading the reports (Display 18): use the
button at the desired file
format to select it and move on to the next input screen.
After the selection of the file format for download, a similar screen ap-
pears and offers five options of what exactly will be downloaded:
• all reports in memory (i. e., since the reports were last deleted)
• the reports that belong to a certain commission or project
• the reports of operations performed by a certain welder
• all reports in a certain range of dates
• all reports in a certain range of reports/report
numbers
When an report type transfer that does not send
all, but only certain reports to the stick was se-
lected, the operator has to define the desired filter
on the next screen. Either he browses through
the reports in system memory to select the de-
sired commission or desired welder. Or he enters
the start and the end of the desired date range
or report range, of which the reports should be
downloaded. Whatever the selected option, the
input screen that appears adapts to the input currently needed to enter
the desired restriction of reports to download. All inputs have to be con-
firmed by touching the
button.
After successful download, the machine displays a message telling the
welder that the process was o.k.
5.2 Showing Reports in Memory, Printing Pipe Label Tags
Using the appropriate option of the configuration menu (see section 4.2),
it is possible to display on the screen the welding
reports saved to memory. A screen like Display 19
appears. The “Status” field reads “WELD P. OK”
if no error occurred, and contains the acronym
“PH - WELD P. OK” (for „Pre-Heat“) if the welding
operation was performed with the pre-heating
feature.
Near the left edge of the Report View screen,
you will find a list of all welding reports currently
in memory. Above this list, the number of the
selected report is given (before the slash), along
with the total number of reports in memory (after
the slash). To move the selection bar through
the list, touch the scrollbar arrows to the right of the list. The longer you
touch them, the faster the bar moves. The data from the selected report
will populate the fields on the right after it was selected by the bar.
To reprint an extra tag of this welding operation in order to identify the
component, touch the
button.
Display 18