background image

 

USER MANUAL 

EZY-LAN 22.07-M:1.0-H:3b/4a/4b-F:3.3.4+

 

 

 

EZY-LAN Wireless alarm panel with Et Wi-Fi + GSM + LTE 

1

 

General

 

EZY-LAN  is  an  alarm  control  unit  that  combines 
the  best  of  the  latest  technologies  available  with 
a pleasant, compact, modern and elegant design. 
It manages up to 64 external  devices, which can 
be divided into a maximum of 8 freely partitionable 
sectors. 
Up  to  32  different  users  can  control  the  control 
unit  via  App  or  keyfob.  The  double  radio  section 
of  the  latest  generation  in  the  868MHz 
bidirectional  multi-channel  band  allows  safe, 
reliable and efficient communication. 
EZY-LAN  gives  its  best  when  connected  to  the 
internet - via Ethernet cable, 2.4GHz Wi-Fi or LTE 
data  connection  -  and  can  be  controlled  in  real 
time from the App on any device. 
Whether it is a smartphone or a tablet (Apple iOS 
and Android), the management and programming 
interface  is  presented  in  the  same  form:  simple, 
intuitive, immediate! 
EZY-LAN integrates a video verification function - 
usable both with radio photo sensors and with IP 
cameras  (Dahua,  Sunell,  Provision)  -  which 
allows you to view within the same App animated 
images relating to alarm events or captured at the 
request of the user. 
EZY-LAN  also  interfaces  with  Shelly  Wi-Fi 
modules  for  home  automation  control  of  lights, 
shutters, gate openings, irrigation or other generic 
electrical loads powered at 230Vac or 12Vdc. 

2

 

Priority of connections

 

The  channel  used  by  the  control  panel  for 
connection to the internet follows a priority logic. 
The Ethernet cable is the primary channel that is 
used if a network cable is connected. 
Wi-Fi  (if  enabled  in  programming)  is  the 
alternative channel used when a network cable is 
not connected. 
The LTE connection with the SIM card (if enabled 
in  programming)  is  the  channel  used  when  the 
Ethernet  /  Wi-Fi  connection  is  absent  or  there  is 
no internet on one of the two connections. 
 
 

3

 

Identification of the parts 

 

 
 

 

 

FRONTAL VIEW 

 
 

 led power 

 led Ethernet 

 led Wi-Fi 

 led GSM + LTE 

 programmable central button 

 multicolor led ring 

4

 

Signals of the luminous ring

 

The  luminous  ring  visible  around  the  central 
button  (6),  if  enabled  during  the  programming 
phase,  provides  information  on  the  status  of  the 
system. 
The  luminous  intensity  of  the  ring  (6)  is  reduced 
after 60 seconds of inactivity of the control unit, to 
reduce  any  disturbance  at  night.  Return  to 
maximum  brightness  as  soon  as you  perform an 
operation on the control unit. 
When the control unit is powered only by battery 
(no  external  power  supply),  in  order  to  reduce 
consumption, 

the 

ring 

(6) 

only 

flashes 

periodically. 

 

Luminous

 ring signals meanings (6) 

Green 

Disarmed 

Green / Blue 
(blinking) 

Disarmed with door open  

Green / Red 
(blinking) 

Disarmed with alarm memory  

Red 

Totally armed 

Orange 

Partially armed 
Exit time (flashing) 
Entry time (flashing) 

Violet (blinking) 

Alarm in progress 

White (blinking) 

Panel in SETUP mode 

Blue (blinking) 

Panel in TEST mode 

 
 
 



Summary of Contents for EZY-LAN

Page 1: ...wered at 230Vac or 12Vdc 2 Priority of connections The channel used by the control panel for connection to the internet follows a priority logic The Ethernet cable is the primary channel that is used if a network cable is connected Wi Fi if enabled in programming is the alternative channel used when a network cable is not connected The LTE connection with the SIM card if enabled in programming is ...

Page 2: ...P for smart devices This is the privileged tool thanks to which you have complete control of the system in real time 8 Using the keyfob remote control Before being used the remote control must have been configured in the control panel by the installer Button 6 requests the system status from the control panel and then displays TOTALLY ARMED Led 1 2 3 4 steady ON DISARMED Led 1 2 3 4 flashing PARTI...

Page 3: ...atus of the control panel Here you can change the arming of the system by using the buttons Disarm Disarm all sectors Stay selection of the sectors to be armed Arm Arm all sectors The icons at the top provide additional information on the system by clicking on the relevant icon Excluded zones indicates the zones currently bypassed Alarm memory indicates the zones that generated an alarm in the las...

Page 4: ... various users Images displays the video verification images of the devices on which the user is enabled and allows to manually request new images Events displays the complete and detailed list of the 5000 panel events 9 3 Home automation control menu From the Home page by pressing the icon right double arrow or swiping to the right you access the home automation control menu The Administrator Use...

Reviews: