Version October 2014
14
EN
agru SP 63-mobile User’s Manual
this message is showing, the machine determines the zero point of the
movable carriage as compared to the position of the fixed carriage, that
will apply for the next welding.
When this reference position/zero point was automatically zeroed and
saved to memory in the control unit, the machine asks the welder to
move the carriage apart, which indicated that the machine has now
been zeroed. To move the carriage apart, press the
cursor key. The
machine returns to the default screen (see Display 3). Welding can now
be started or parameters can be edited.
4.2 Configuring the Machine
In the default screen (Display 3), the key parameters of the last welding
are shown (material, diameter, and wall thickness of the welded pipe)
along with the date and time. The last line of the display can be switched
to showing the current temperature and the current percentage of heat-
ing performance by pressing the number key 1 and to showing the ap-
plied force by pressing the key 2. Both keys are toggle switches, i.e. will
switch the fourth display line back to what is reproduced in Display 3
when pressed again.
In Display 3, the welder has the possibility to:
•
immediately start a welding process that will be performed with
the same welding parameters as the previous welding (press the
START/SET key and move on to section 4.6);
•
enter new traceability data, including another welder ID code, for
the next welding (press the STOP/RESET key and move on to sec-
tion 4.3);
•
change the machine settings in the configuration menu (press the
MENU key);
Info
Other functionalities that are called when the default screen is
showing, are explained below in this booklet, including how to
call them from this screen.
After the MENU key was pressed, Display 4 appears and allows selecting
one of the various parts of the configuration menu. The options under
“Settings” of the configuration menu are immediately accessible, the op-
tions under “Advanced Settings” will be displayed only after an access
code was entered and confirmed by START/SET. The menu has the items
listed in the following table. The items under “Machine Data” are not listed,
as they are relevant for setting up and servicing the machine only, not
for normal operation, and, therefore, protected by another access code,
which will be disclosed to authorized personnel only.
To toggle from « On » to « Off » or vice versa for an option, press the
cursor key, to open a submenu or go to an additional screen for an
option, which is indicated by the letter – M –, press the MENU key.
Any changes in the configuration menu are saved to memory and will
be used by the machine in the future when the menu is quit by pressing
the START/SET key. By qutting it by pressing the STOP/RESET key, the
previous state is kept and no changes, if there were any, are saved.
Designation
Setting
Description / Data to be entered
—— “Settings” submenu ————————
Number of Tags
Menu
In a sub-menu, the number of tags to be printed after welding for
sticking them onto the welded pipes, can be selected.
Unit of Length
(mm / inch)
Menu
In a sub-menu, the unit of length used for displaying and saving
welding data can be selected.
Display 5
**** Main Menu *****
>Settings -M-
Adv. Settings -M-
Machine Settings-M-