INSTRUCTIONS FOR USE
AGS 400-1200 EN
Rev.12/2018
47
10.2
USE
Before turning on the pump, make sure that the main valve on pressure regulator is closed (return to
reservoir.
Never turn on the pump’s drive when the setting on the regulator enables full load on the pump.
Turn on the pump and let it run for approximately one minute under minimum pressure in order to
aerate the pump and the inlet and the outlet pipes. Only then can you put full load on the pump.
Be careful not to exceed the maximum allowed pressure and the maximum allowed rpm of 540. On the
opposite, the manufacturer cannot be held responsible for any kind of damage that could occur.
10.3
AFTER USE
Some chemical agents can shorten the durability of some vital parts of the pump such as rubber
membranes and other rubber seals. Therefore a thorough washing of the pump after each single
spraying is recommended. To do this, you will need to pump some clean water through the pump. Let
the pump operate at working pressure for several minutes. Lower the pressure and let the pump operate
for approximately one minute to blow out the rest of the liquid.
During winter, leave all of the water out of the pump and/or protect the pump against freezing (see
chapter 15.6.5).
10.4
PISTON MEMBRANE PUMPS BM 150/20
Pumps type BM 150/20 are low-pressure piston membrane pumps, made of materials that have been
tested by the factory. The pumps are suitable for pumping of insecticides or liquid fertilizers which are
used in farming.
10.5
TEHNICAL DATA
Pump type
BM 65/30
BM 105/20
BM 150/20
Flow rate (l/min)
68
93
149
Max. OPERATING PRESSURE (bar)
25
20
20
Max. RPM (n/min)
540
540
540
REQUIRED POWER (kW)
3,2
3,5
5,5
NO. OF PRESS. MEMBRANES (pc)
2
3
4
Weight (kg)
13,2
14,8
24,4
Oil
HIPOIDOL
SAE 90
MOTORNO
SAE 15 W30
WARNING: The machine IS NOT SUITABLE FOR LIQUID FERTILIZERS! If
you intend to make an exception, we recommend that you consult the technical
service department!