INSTRUCTIONS FOR USE
AGS 400-1200 EN
Rev.12/2018
30
The valve is designed to wash the packaging of liquid plant protection chemicals. It is installed inside
the filling container and connected with the valve on the filling container (8) through a hose. The
packaging is washed by placing it over the nozzle (9) and administering water through the valve (8).
The rinsing nozzle can also be used to penetrate the protective film under the packaging lid to prevent
contamination of the surrounding area.
7.9
DESCRIPTION OF SETTING OF VALVES FOR SPRAYING OR CLEANING
7.9.1
SPRAYING
Figure 16: AGS 400 EN functions diagram
Figure 17: Spraying label
By means of the three-way valves (1 and 2), release the spray from the main tank (9) through the filter
(4) and the pump (5) into the pressure regulator (6). Open the spray mixing valve (11) for individual
nozzle sections (8). The flow direction through the three-way valve is indicated with an
arrow
on the
valve lever. Adjust the selector valve (3) so that the excess liquid from the regulator is directed
towards the main reservoir. For a detailed description of the regulator, see chapter 9.2.