INSTRUCTIONS FOR USE
AGS 400-1200 EN
Rev.12/2018
37
AGS 800-1200 EN
Filling through the lid of the main reservoir (1) and the filter (2)
.
Figure 28: Main reservoir filling AGS 800-1200 EN
WATER DRYING PROCEDURE IN THE MAIN RESERVOIR
The reservoir is filled by drawing water through the pump.
Remove the closing cap (1) and attach the suction hose to the
fitting (2) and secure it with a hose clamp. Attach the fitting (2)
with the hose to the attachment (3) and secure it with side handles.
− Move the lever of the selector valve to position 1.
− Open the lever of the valve for external supply to position 4
(MAIN RESERVOIR FILLING).
− Move the lever of the selector valve to position 6.
− When the reservoir is full, move the lever of the external supply
valve back to position 3 and remove the fitting with the hose.
WARNING: Only extract water from
a pool or a water basin, never from a
pressurized hydrant. Otherwise the
pump may be damaged!