INSTRUCTIONS FOR USE
AGS 400-1200 EN
Rev.12/2018
71
12.5.4
WORK WITH CLOSED BOOMS ON ONE SIDE
In case of using spraying equipment with booms closed on one side, you must first activate block, lift
equipment in position of activation of mechanism with wheel, open first booms of equipment
(mechanical safeties against opening of booms in transport position). Now open the booms on desired
side. Use hydraulic levelling to adjust spraying equipment. Begin spraying process.
12.6
SPRAYING SECTIONS AND NOZZLES
Figure 12.30
Both types of booms are equipped with five sections. The distribution of the spraying sections on the
boom allows for a minimum pressure drop in the hoses and a maximum distribution of the spray agent
to individual nozzles (Figure 12.30). The hoses are routed to the nozzles from the directional control
valve on the pressure regulator. The hoses are attached to the valve by means of quick couplings.
12.6.1
CONNECTION SCHEME
Connection of sections is displayed in Figure 12.30
Working width
(m)
12
15
Number of sections
5
Number of nozzles
per section
5-6-4-6-5
6-7-4-7-6