106
8210-10003 R0
3.37.2 Install the Tank (for outside USA)
1. Secure the tank (6) to the tank bracket with gear clamps (4).
2. Attach the 1/4" hose barb (7) to the tank outlet.
3. Connect the 1/4" fuel line (9) to the hose barb with hose clamp (8).
4. Insert the square plug (10) into the hole in the bottom of the tank nearer to the spout. To install primer
bulb, see
Section 3.37.3 – Install the Primer Bulb on page 107
7
8
9
4
6
10
To Primer Bulb
4
36" Gear Clamp
8
1/2" Hose Clamp
6
Gas Tank — 22 x 14 x 11.5 — 53 L (14 gal) —
red
9
1/4" ID Fuel Line — 14'
7
1/4" MPT x 1/4" Hose Barb
10
Square Plug (threaded)
Hardware Kit: PARTK-15-96
UCX3 S-DRIVE FIELD LOADER – PORTABLE GRAIN BELT CONVEYOR