:Anapurna M
4F
- Operator Manual
Stay ahead. With Agfa Global Services.
50
Maintenance - Maintenance Routines
The bubble on the lamp glass should stay on the inner side
(should not face the media while printing).
Put the wires back into the connectors and make sure they are
secure.
Put the lamp assembly
back into the carriage
housing.
Reconnect the UV data
cable on the top of the
lamp assembly.
Turn the P
ower ‘ON’ &
the engine is ready for
printing.
3.14
Cleaning the UV Lamp Crystal Glass.
Turn the lamps OFF and wait till they cool down.
Press ESC so that engine is in OFFLINE mode.
Press F4 (Cleaning/ IP Set).
Press F1 (Head UP/DOWN) : The carriage will move up
(to the maximum possible position).
Press the Emergency Button to power OFF the engine.
Turn all the 2 way Ink Val
ves to ‘S’ Position; leave the
Solution Valve to ‘I’ position.
Take a clean rag, put some isopropyl on the rag and
clean the glass under the lamp housing (you can ac-
cess the glass as the carriage is at the top most posi-
tion).
Make sure the glass is clean, if not you might need to
use a scraper very gently to take out any ink residue.
To clean the glass from the inner side, take the lamp
assembly out of the housing (as described in .1 Re-
placing the uv lamps).
Observe: there are two pneumatic tubes
going into the lamp housing at the
top; one of them has a red sticker and
the other has a yellow sticker (We will
call them the Yellow Tube and the Red
Tube).
Take the yellow tube out of the con-
nector by pressing the connector in and
pulling the tube out.
Also, take the red tube out and put it in
place of the Yellow tube.
Please be aware, when you take the Red tube out, the compressed air will start
leaking – no need to worry, just insert the Red tube in place of Yellow Tube;
keep the Yellow Tube hanging outside.
The moment you put the Red Tube in, the shutters will open and you can access
the glass from the top.
Take a clean rag with some isopropyl and clean the glass from the inner side;
making sure the glass is clean.