www.agfagraphics.com
30
4.3.1
Vacuum control print heads
4.3.2
Ink and storage flush flow control
4.4 iGUI Touch screen control Panel: Common elements
4.4.1
Status and error indicators
The standard negative pressure value (= vacuum)
is preset in the factory for the default ink and
should not be changed unless performance issues
require it or other ink types are used.
• Pressure value color ink circuits: -.038 Bar.
• Pressure value white ink circuit: -.048 Bar.
The storage flush has a valve (red label) to control the flow of storage
flush.
Position lever
• Vertically up (
CLOSE
): delivery of storage flush closed.
• Vertically down (
SOL
.): delivery of storage flush opened.
Each color ink circuit has a valve (yellow label) to control the flow of
ink or storage flush to the print head.
Position lever
• Vertically up (
CLOSE
): delivery of ink or storage flush closed.
• Horizontally middle (
INK
): delivery of ink opened.
• Vertically down (
SOL
.): delivery of storage flush opened to clear a
blocked print head.
The status indicators for the modules
of the printer are located in the
upper left corner of the screen.
• Indicator is lit green: status
OK or active.
• Indicator is lit red: status
NOT OK or not active.
Error
In case of an error:
1 Press “Error” to check which
malfunction has occurred.
2 Fix the malfunction.
3 Press "Clear Error" to clear
the error in the program.